摘要
详细介绍了合成高分子类预铺防水卷材在施工中存在的连接问题、缺陷及应对措施,主要针对双缝焊飞边、双缝焊空腔、对接缝等容易出现渗漏问题的部位,提出了切除飞边、满焊接、封堵空腔、包裹对接缝等措施,为合成高分子类预铺防水卷材的施工应用和质量验收提供参考。
This paper detailed introduces connection issues,defects and countermeasures during the installation of pre-applied polymer waterproofing membranes,mainly focuses on the areas prone to leakage such as double-welded flash edges,unwelded cavities in double seams and butt joints.The paper proposes techniques including flash edge trimming,full-length welding,cavity sealing and joint wrapping,providing practical references for construction practices and quality acceptance of polymer-based pre-applied waterproofing membranes.
作者
杨朝
彭方灵
崔莹
王盈莹
Yang Zhao;Peng Fangling;Cui Ying;Wang Yingying(Beijing Oriental Yuhong Waterproof Technology Co.,Ltd.,Beijing 101111,China)
出处
《中国建筑防水》
2025年第4期45-48,52,共5页
China Building Waterproofing
基金
北京市科技计划“新建地铁工程渗漏防控新型技术研究与示范”Z221100005222033。
关键词
合成高分子类预铺防水卷材
搭接
对接
焊接
双缝焊
polymer-based pre-applied polymer waterproofing membrane
lap joint
butt joint
welding
double seam welding