期刊文献+

高校实验用锂离子电池风险辨识与防控策略

Risk identification and control measures for lithium-ion battery in university laboratories
在线阅读 下载PDF
导出
摘要 随着储能产业的进一步发展,锂离子电池的风险逐步引起了人们的关注。在实验室安全管理过程中,学校层面和实验室层面均存在对锂离子电池危险性认识不足、对火灾隐患缺乏预判的现象,可能导致实验室锂离子电池火灾事故发生。从热失控特征和危害出发,采用失效模式与效应分析法(Failure Mode and Effects Analysis, FMEA)对锂离子电池实验室进行了风险辨识,提出了防控措施,以期提升高校锂离子电池安全管理水平,提高实验室人员安全意识,保障实验室安全稳定运行。 With the further development of the energy storage industry,the risks of lithium-ion batteries have gradually attracted people s attention.Inadequacy of dangerous awareness and prediction of fire hazards in the process of laboratory safety management may lead to laboratory lithium-ion battery fire accidents.Starting from the characteristics and hazards of thermal runaway,this article uses Failure Mode and Effects Analysis(FMEA)to identify the risks in lithium-ion battery laboratories.Prevention and control measures were put forward to improve the safety management level,enhance the safety awareness of laboratory personnel,and ensure the safe and stable operation of the laboratory.
作者 刘钊 LIU Zhao(Department of Laboratory Management,North China Electric Power University,Beijing 102206,China)
出处 《实验室科学》 2025年第1期148-153,共6页 Laboratory Science
基金 华北电力大学2023年实验室建设与管理研究项目。
关键词 高校实验室 锂离子电池 失效模式与效应分析法 安全管理 university laboratory lithium-ion battery FMEA safety management