神经束内微电极采集家兔周围神经电信号的实验研究 被引量:5

Experimental study on harvesting the electrical signal of peripheral nerve at rabbits by intrafascicular micro-electrodes
原文传递
导出
摘要 目的 介绍采用神经束内微电极 ,采集周围神经的电生理信号的动物模型。方法 对 12只家兔 ,在放大 10倍手术显微镜下将外部绝缘、直径为 60 μm的金属丝 (95 %铂、5 %铱合金 )直接插入其坐骨神经束中作为记录电极 ,神经束外用同样微电极为参考电极 ,远端连接肌电图仪。在神经束插入点近端及远端以钩状电极刺激 ,记录神经束电信号。结果 在 11只家兔后肢中成功地导出电信号 ,1只失败。分析导出的电信号其波形均具有运动及感觉神经动作电位的特征。结论 神经束内微电极可以稳定地记录到周围神经的电信号 。 Objective To set up an animal model in harvesting the electrical signal of peripheral nerve by intrafascicular micro-electrodes. Methods Twelve rabbits were involved. Recording electrode fabricated from external insulated wire 60 μm in diameter ( 95% Pt-5% Ir alloy ) was inserted directly under operating microscope by 10X magnification into the fascicle of the sciatic nerve, while another similiar electrode was placed outside the fascicle as reference electrode. Both distal ends were connected with electromyogram. Stimulating with 2 hook electrodes at the proximal and distal points from the inserted electrode, the signal was recorded. Results Electrical signal was successfully recorded in 11 legs of rabbits, with failure in 1 case. The signals recorded had the characteristic of the motor or sensory nerve action potentials. Conclusions Intrafascicular micro-electrodes can record the electrical signal of peripheral nerve stably. It could serve as a method of harvesting and assessment for the electrical signal recording of peripheral nerve.
出处 《中华手外科杂志》 CSCD 2002年第4期245-247,共3页 Chinese Journal of Hand Surgery
基金 国家自然科学基金重点项目资助项目 (39930 0 70 )
关键词 周围神经 诱发电位 动物实验 神经束内微电极 多自由度电子假肢 Peripheral nerves Evoked potentials Animals,laboratory Intrafascicular electrodes
  • 相关文献

参考文献12

  • 1Chen ZW, Hu TP. A reconstructeddigit by transplantation of a second toe for control of an electromechanical prosthetichand. Microsurgery,2002,22:5-10.
  • 2Vinet R, Lozac HY, Beaudry N, et al. Design methodology for a multifunctional handprosthesis. J Rehabil Res Dev,1995,32:316-324.
  • 3Silcox DH, Rooks MD, VoGel RR, et al. Myoelectric Prostheses. A long-term follow-upand a study of the ase of alternate prosfheses. J Bone Joint Surg,1993,75:1781-1789.
  • 4Malmstrom JA, McNaughton TG, Horch KW. Recording Properties and biocompatibility ofchronically implanted polymer-based intrafascicular electrodes. Ann BiomedEng,1998,26:1055-1064.
  • 5Malagodi MS, Horch KW, Schoenberg AA. An intrafascicular electrode for recording ofAction potentials in peripheral nerves. Ann Biomed Eng,1989,17:397-410.
  • 6Guillory KS, Normann RA. A 100-channel system for real time detection and storageof extracellular spike waveforms. J Neurosci Methods,1999,91:21-29.
  • 7Branner A, Normann RA. A multielectrode array for stimulation and recording frommudpuppy spinal roots. J Neurosci Methods,2000,96:47-55.
  • 8Yoshida K , Horch K. Closed-loop of ankle position using muscle afferent feedbackwith functional neuromuscular stimulation. IEEE Trans Biomed Eng,1996,43:167-176.
  • 9Goodall EV, Lefurge TM, Horch KW. Information contained in sensory nerve recordingsmade with intrafascicular electrodes. IEEE Trans Biomed Eng,1991,38:846-850.
  • 10McNaughton TG, Horch KW. Mentallized polymer fibers as leadwires andintrafascicular microelectrodes. J Neurosci Methods,1996,70:103-110.

二级参考文献15

  • 1VINET R,LOZAC'H Y,BEAUDRY N,et al.Design methodology for a multifunctional handprosthesis[J].J Rehabil Res Dev,1995,32:316-324.
  • 2UELLENDAHL JE.Upper extremity myoelectric prosthetics[J].Phys M ed Rehabil Clin NAm,2000,11:639-652.
  • 3GOODALL EV,LEFURGE TM,HORCH KW.Information contained in sensory nerve recordingsmade with intrafascicular electrodes[J].IEEE Trans Biomed Eng,1991,38:846-850.
  • 4MCNAUGHTON TG,HORCH KW.Mentallized polymer fibers as leadwires and intrafascicularmicroelectrodes[J].J Neurosci Methods,1996,70:103-110.
  • 5MALMSTOM JA,MCNAUGHTON TG,HORCH KW.Recording Properties and biocompatibility ofchronically implanted polymer-based intrafascicular electrodes[J].Ann BiomedEng,1998,26:1055-1064.
  • 6MALAGODI MS,HORCH KW,SCHOENBERG AA.An intrafascicular electrode for recording ofAction potentials in peripheral nerves[J].Ann Biomed Eng,1989,17:397-341.
  • 7GUILLORY KS,NORMANN RA.A 100-channel system for real time detection and storage ofextracellular spike waveforms[J].J Neurosci M ethods,1999,91:21-29.
  • 8GOODALL EV,HORCH KW.Separation of action potentials in multiunit intrafascicularrecordings[J].IEEE Trans Biomed Eng,1992,39:289-295.
  • 9MIRFAKHRAEI K,HORCH K.Recognition of temporally changing ac tion potentials inmultiunit neural recordings[J].IEEE Trans Biomed E ng,1997,44:123-131.
  • 10GOODALL EV,HORCH KW,MCNAUGHTON TG,et al.Analysis of si ngle-unit firing patternsin multi-unit intrafascicular recordings[J].Med Biol Eng Comput,1993,31:257-267.

共引文献4

同被引文献24

引证文献5

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部