期刊文献+

复兴号CR200J型动车组空调过流故障原因分析及整改建议 被引量:1

Cause Analysis and Improvement Suggestions of Overcurrent Fault in Air Conditioning of Fuxing CR200J EMU
在线阅读 下载PDF
导出
摘要 复兴号CR200J型动力集中动车组列车供电方式采用DC 600 V制式,在实际运用过程中,单车偶发空调过流故障,文章从空调负载电流特性、车下逆变器输出特性、动车DC 600 V列供电源输出特性以及PLC空调保护机制等方面,对空调制冷过流故障进行了理论分析和试验验证,并提出了整改建议。 The DC 600 V mode is adopted in the power supply mode of Fuxing CR200J power-concentrated EMU.In the practical application process,the air conditioning overcurrent fault occurs occasionally in a single vehicle.The theoretical analysis and experimental verification of overcurrent fault of air conditioning refrigeration are carried out from the aspects of the load current characteristics of air conditioning,the output characteristics of the inverter under the vehicle,the output characteristics of the DC 600 V train power supply of the motor vehicle and the PLC air conditioning protection mechanism,and the rectification suggestions are put forward.
作者 赵志春 ZHAO Zhichun(Jinan Vehicle Depot of China Railway Jinan Bureau Group Co.,Ltd.,Jinan 250000,China)
出处 《铁道车辆》 2022年第5期97-100,共4页 Rolling Stock
关键词 动力集中动车组 空调 过流故障 原因分析 整改建议 power-concentrated EMU air conditioning overcurrent fault cause analysis rectified suggestion