摘要 随着水资源紧缺的加剧和再生水回用技术的日趋成熟,城市污水经处理后作为非常规水源逐渐得到认同,污水处理要求也更加严格。杭州临平净水厂服务范围内纳入了部分印染等工业废水,通过对其进水水质组分的测定分析,选择有效合理的处理工艺,满足了高标准的出水要求。 With the increasing shortage of water resources and the maturity of reclaimed water reuse technology,the treatment of urban sewage as an unconventional water source has been recognized by people,and the treatment standards are more strict.Some printing and dyeing industrial waste water is included in the service scope of Hangzhou Linping sewage treatment plant.Through the determination and analysis of its influent water quality components,an effective and reasonable treatment process is selected to meet the high standard effluent requirements.
作者 牛樱 李胜 Niu Ying;Li Sheng(Beijing General Municipal Engineering Design&Research Institute Co.,Ltd.,Guangzhou 510060,China)
出处 《给水排水》 CSCD 北大核心 2020年第11期45-49,共5页 Water & Wastewater Engineering
关键词 水质分析 有机污染组分 惰性组分 处理工艺 Water quality analysis Organic pollutant components Inert components Treatment process
  • 相关文献

参考文献2

二级参考文献44

  • 1曹海彬,张代钧,卢培利.活性污泥模型进水COD组分的测定方法[J].重庆大学学报(自然科学版),2005,28(9):83-87. 被引量:10
  • 2Henze M, Gujer W, Mino T, et al. Activated Sludge Moedels ASM1, ASM2, ASM2d and ASM3 [R]. London: IAW Publishing, 2000.
  • 3Orhon D, Cokgor E U. COD fractionation in wastewater characterization-the state of the art [J]. J Chem Tech Biotechnol, 1997, 68(3) : 283-293.
  • 4Cokgor E U, Sozen S, Orhon D, et al. Respirometric analysis of activated sludge behaviour-I: assessment of the readily biodegradable substrate [J]. Water Res, 1998, 32(2) : 461-475.
  • 5Roeleveld P J, van Loosdercht M C M. Experience with guidelines for wastewater characterization in the Netherlands [ J ]. Water Sci Technol, 2002, 45(6): 77-87.
  • 6Brdjanovic D, van Loosdercht M C M, Versteeg P, et al. Modeling COD, N and P removal in a full-scale WWTP Haarlem Waarderpolder [J]. Water Res, 2000, 34(3): 846-858.
  • 7Salem S, Berends D, Heijnen J J, et al. Model-based evaluation of a new upgrading concept for N-removal [ J]. Water Sci Technol, 2002, 45(6) : 169-176.
  • 8Makinia J, Swinarski M, Dobiegala E. Experiences with computer simulation at two large wastewater treatment plants in northern Poland [J]. Water Sci Technol, 2002, 45(6) : 209-218.
  • 9Makinia J, Rosenwinkel K H, Spering V. Long-term simulation of the activated sludge process at the Hanover-Gummerwald pilot WWTP [J]. Water Res, 2005, 39(8): 1489-1502.
  • 10Wang C, Zeng Y, Lou J, et al. Dynamic simulation of a WWTP operated at low dissolved oxygen condition by integrating activated sludge model and a floc model [J]. Biochem Eng J, 2007, 33(3) : 217-227.

共引文献35

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部