摘要
由于使用地点远离市区,且没有市电输送,对野外监测设备电源系统的可靠性要求更高一些。系统发电量、用电量的配置方案直接影响电源系统的可靠性。本文分析了在使用地点不同月份内日均气温及降水量条件下电源系统的电力平衡问题,对造成电源系统故障的最大配件—铅蓄电池的故障进行了分析,并提出了使用建议。
Owing to some places far from cities and no city power transmission,it is necessary to keep higher reliability of the power system used in the field monitoring equipment.The disposition scheme for generated energy of the power system has direct effects on its reliability.In this paper,the balanced problem of the power system is analyzed in terms of daily air temperature and amount of precipitation in different places and month,and the system faults caused by lead-acid battery failures are also analyzed.In addition,some suggestions related to the usage of the system and batteries are put forward in the paper.
作者
李亚辉
孙威
张利芳
王丽斋
张旭东
刘建楼
LI Yahui;SUN Wei;ZHANG Lifang;WANG LiZhai;ZHANG Xudong;LIU Jianlou(Fengfang Co.,Ltd,Baoding Hebei 071057,China)
出处
《蓄电池》
2020年第3期136-139,共4页
Chinese LABAT Man
关键词
野外
监测设备
电源系统
配置方案
电力平衡
故障
铅蓄电池
field
monitoring equipment
power source system
disposition scheme
power balance
failure
lead-acid battery