摘要
针对一2×600 MW直接空冷机组夏季高温时段背压高、煤耗高的现状,借鉴直接空冷机组的改造经验,将中水作为尖峰系统的补水,达到了降低机组运行背压、提高机组夏季发电负荷、降低煤耗的目的,同时评估了改造后机组的经济效益。
In view of the high back pressure and coal consumption of a 2×600 MW direct air cooling unit in the high temperature period in summer,this paper used the transformation experience of the direct air cooling unit for reference,took the reclaimed water as the water supplement of the peak system,achieved the purpose of reducing the unit operation back pressure,increasing the unit summer power generation load and reducing the coal consumption,and evaluated the economic benefits of the unit after transformation.
作者
张兴隆
ZHANG Xinglong(Shanxi Electric Power Engineering Co.,Ltd.,China Energy Engineering Group,Taiyuan 030001,Shanxi,China)
出处
《能源与节能》
2020年第4期52-53,57,共3页
Energy and Energy Conservation
关键词
直接空冷机组
尖峰冷却系统
机组运行背压
经济效益
direct air cooling unit
peak cooling system
unit operation back pressure
economic benefits