摘要
文章针对DZZ3型区域自动气象站出现的1次多个小时內数据错误且连续保持不变的故障,通过对电源系统、通信系统和主采集器等方面的排查和分析,找出了故障原因,并提出排除方法、处理流程、解决措施以及注意事项。为其他台站业务人员处理此类故障提供参考。
Aiming at the data error of DZZ3 regional automatic weather station in more than one hour and keeping constant continuously,this paper checks and analyses the power supply system,communication system and main collector,finds out the causes of the fault,and puts forward the methods of eliminating,processing flow and solving measures,as well as the matters need to be attention,which can provide reference for other station operators to deal with such failures.
作者
魏明明
孔海洋
陈伟山
郝翠萍
刘春涛
Wei Minging;Kong Haiyang;Chen Weishan;Hao Cuiping;Liu Chuntao(Qingdao Laoshan Meteorological Bureau of Shandong,Laoshan 266102;Shanghai Meteorological Instrument Limited Company,Shanghai 200120)
出处
《气象水文海洋仪器》
2019年第3期109-111,共3页
Meteorological,Hydrological and Marine Instruments
关键词
自动气象站
故障
排除
automatic weather station
fault
troubleshooting