摘要 按照HJ/T55或GB/T16157的相关规定,用固定量0.12mol·L^-1盐酸溶液吸收采集固定污染源废气中三甲胺。分取样品溶液10.00mL,移至顶空瓶中,加入氯化钠3.2g和硫酸钾1.0g,并用微量注射器加入质量分数为50%的NaOH溶液500μL和氨水100μL,立即密封顶空瓶,在顶空平衡温度为80℃,平衡时间为30min的条件下进行顶空采样。选择CP-Volamine石英毛细管色谱柱进行三甲胺及其他5种研究的脂肪胺类化合物的定量分离,采用氢火焰离子化检测器(FID)进行检测。分别按HJ/T55及GB/T16157规定的方法各取三甲胺标准气体20L,分别进行7组平行试验,测得前一采样方法的检出限[tn-1,0.99)×s]为0.004mg·m^-3,后一采样方法的检出限[tn-1,0.99)×s]为0.02mg·m^-3。另取高浓度(0.510μmol·mol^-1)、中浓度(0.102μmol·mol^-1)及低浓度(0.0102μmol·mol^-1)等3种浓度的三甲胺标准气体,按规定方法采样并分析6次,计算得三甲胺的回收率在90.1%~108%之间,测定值的相对标准偏差(n=6)在2.2%~6.7%之间。应用此方法分析实际样品,测定结果表明该方法能满足国家标准GB14554-93及天津市和上海市两地方标准对恶臭污染物排放的规定,并配合上述标准的执行。 Trimethylamine (TMA) in exhaust gas at stationary pollutive sources were collected either by the method given in HJ/T 55 or GB/T 16157 with definite amount of 0.12 mol·L^-1 HC1 solution as absorbent. An aliquot of 10.00 mL of the dil. HC1 solution containing TMA was taken and transferred into the head-space flask of the GC instrument, and 3.2 g of NaCl and 1.0 g K2SO4 were added and 500 μL of NaOH (w, 50%) solution together with 100 p.L of aq. ammonia were added successively. The head-space flask was then sealed hermetically and the HS-sampling was carried out at 80℃ for 30 min. CP-Volamine quartz capillary chromatographic column was selected for quantitative separation of TMA and other 5 aliphatic amines added for testing. FID was adopted for detection of response signals. To test for detection limit of the proposed method with collection of TMA in exhaust gas by the methods given in HJ/T 55 and GB/T 16157, 20 L of TMA standard gas were collected by the 2 methods separately, and 7 sets of parallel determinations were performed by the GC analysis by taking 10.00 mL aliquots from the HC1 solution absorbed with TMA. Detection limit [tn-1,0.99)×s] of 0.004mg·m^-3 was found for collection of TMA by the method given in HJ/T 55, and detection limit [tn-1,0.99)×s] of 0.02mg·m^-3 was found for collection of TMA by the method given in GB/T 16157. Standard TMA gas samples with 3 concentration levels of 0.510 μmol·mol^-1 , 0.102 μmol·mol^-1 and 0.010 2 μmol·mol^-1 were collected and analyzed by thd given method for 6 parallel determinations and values of recovery found were in the range of 90.1% 108%, and RSDs found were ranged from 2.2% to 6.7%. As shown by the results obtained by analyzing several substantial samples, the proposed method was feasible to be used in supervision and controlling the ejection of TMA in atmosphere, and was effective in meeting with the requirements given in the national standard GB 14554-93 and in local standards of Shanghai and Tianjin Muncipalities pertaining regulations of ejection of stenchy pollutants.
作者 张存良 李红莉 岳太星 丁君 翟振国 侯晨晓 侯聪 ZHANG Cunliang;LI Hongli;YUE Taixing;DING Jun;ZHAI Zhenguo;HOU Chenxiao;HOU Cong(Shandong Provincial Environment Monitoring Center,Jinan 250101,China)
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2019年第7期778-783,共6页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 顶空-气相色谱法 三甲胺 固定污染源 废气 HS-GC trimethylamine stationary pollutive source exhaust gas
  • 相关文献

参考文献4

二级参考文献15

  • 1刘洪晃.初试阈值测定[J].酿酒科技,1995(4):89-90. 被引量:4
  • 2侯定远,唐剑飞.直接进水样气相色谱法测定水和工业排水中有机污染物[J].中国环境科学,1995,15(5):383-386. 被引量:10
  • 3国家环保局有毒化学品管理办公室 化工部北京化工研究院环保科研所.化学品毒性法规环境数据手册[M].北京:中国环境科学出版社,1992.552-610.
  • 4BAO Jingling(包景岭), ZOU Kehua(邹克华), WANG Liansheng(王连生). Odor environment management and pollution control (恶臭环境管理与污染控制)[M]. Beijing: China Environmental Science Press, 2009: 141.
  • 5LEONARDOS G, KENDALL D, BARNARD N. Odor threshold determination of 53 odorant chemicals[J]. Journal of the Air Pollution Control Association, 1969, 19(2): 91-95.
  • 6HELLMAN T M, SMALL F H. Characterization of the odor properties of 101 petrochemicals using sensory method[J]. Journal of the Air Pollution Control Association, 1974, 24(10): 979-982.
  • 7YOSHIO N. Measurement of odor threshold by triangle odor bag method [C]//Odor Measurement Review, 2004:118 - 127[2014 -05 - 16]. http ://orea. or. jp/en/PDF/Odor _ Measurement-Review,. pdf.
  • 8周玉芝,邵光,王勺,牟世芬.低分子量有机胺的离子色谱法研究[J].色谱,1997,15(3):243-245. 被引量:14
  • 9龚淑贤.大气中残留有机磷农药的捕集[J].色谱,1990,8(5):344-344. 被引量:3
  • 10冯忆,顾海东,周振梅.环境中三甲胺的气相色谱测定[J].环境监测管理与技术,1999,11(2):28-29. 被引量:13

共引文献148

同被引文献57

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部