期刊文献+

临床检验室内质量控制策略设计新工具-分析批长度Westgard西格玛规则 被引量:21

New Internal Quality Control Rules Design Tool in Clinical Laboratory-Westgard Sigma Rules with Run Size
暂未订购
导出
摘要 为高通量连续工作分析仪建立限定区间统计质量控制计划时,分析批长度(或质量控制频率)的优化是一项重要内容。合理的分析批长度有助于及时检出误差,降低系统误差所致的不可接受患者结果数,从而最小化患者风险。但目前缺乏简单实用的工具帮助实验室优化分析批长度,导致实验室的质控实践与理论间存在明显的差异。对此,Westgard以不可接受患者结果最大预期数目[MaxE(Nuf)]为基础,将Sigma度量分析批长度列线图与Westgard西格玛规则流程图相结合,建立了分析批长度Westgard西格玛规则流程图。该工具图简单直观,实验室根据检测方法的Sigma度量值即可选择适当的质控规则、每次质控测定数量以及分析批长度,以此为连续工作分析仪建立科学客观的限定区间质控策略,达到患者风险最小化的目标。 For the bracketed statistical quality control(SQC)of high-volume continuous production analyzers,it is important to optimize the run size or the freque-ncy of QC.The run size appropriate for the different SQC procedures can detect error condition timely,which will reduce the number of unacceptable patient results during the existene of an undetected error condition and minimize the patient risk〉However,the lack of simple and practical tools to optimize run size makes it difficult for laboratory practice〉Based on the maximum expected number of unacceptable final patient results[MaxE(Nuf)],Westgard created a diagram called Westgard Sigma Rules with Run Size,which combines Sigma-Metric Run Size Nomogram and Westgard Sigma Rules.Once the sigma quality of the tests and methods in laboratories were calculated.The simple practical tools can help laboratory to select the right control rules,the right number of control measurements and the right run size for bracketed SQC of continuous production analyzers so as to realize the patient risk minimization.
作者 张莉 蒙立业 杨培 黄亨建 ZHANG Li;MENG Li-ye;YANG Pei;HUANG Heng-jian(Department of Medical Examination,West China School of Medicine,Sichuan University Chengdu 610041,China;Department of Laboratory Medicine,West China Hospital,Sichuan University,Chengdu 610041,China)
出处 《现代检验医学杂志》 CAS 2019年第2期137-139,共3页 Journal of Modern Laboratory Medicine
关键词 患者风险 分析批长度Westgard西格玛规则 patient risk westgard sigma rules with run size
  • 相关文献

参考文献1

二级参考文献8

  • 1Westgard JO,Groth T. Design and evaluation of sta- tistical control procedures:applications of a computer "quality control simulator" program [ J ]. Clin Chem, 1981,27(9) .. 1536-1545.
  • 2Westgard JO,Groth T. Power functions for statistical control rules[J]. Clin Chem,1979,25(6) :863-869.
  • 3Koch DD, Oryall J J, Quam EF, et al. Selection of med- ically useful quality control procedures for individual tests done in a multitest analytical system[J]. Clin Chem,1990,36(2) :230-233.
  • 4Westgard JO, Quam EF,Barry PL. Selection Grids for planning quality control procedures[J]. Clin Lab Sci, 1990(3) : 271-278.
  • 5Westgard JO. Charts of operational process specifica tions (OPSpecs Charts) for assessing the precision, accuracy,and quality control needed to satisfy profi- ciency testing criteria[J]. Clin Chem, 1992, 38 (7) : 1226-1233.
  • 6Westgard JO,Stein B. Automated selection statistical qualitycontrol procedures to assure meeting clinical or analytical quality requirements[J]. Clin Chem, 1997, 43(2) ..400-403.
  • 7Westgard JO. Assuring the Right Quality Right. Cha- pter 11. How to use the EZRules 3 computer program [M]. Madion WI: Westgard Quality Corporation, 2007.
  • 8Lenters-Westra E,Slingerland RJ. Three of 7 hemo- globin Alc point-of-care instruments do not meet generally accepted analytical performance criteria [J]. Clin Chem,2014,60(8) : 1062-1072.