摘要
用电渗析法对膜拟的L -谷氨酸废水进行分离处理 ,得出描述电渗析器特性的经验模型 .并就几种因素对设备的极限电流密度和过程性能的影响进行研究 ,得出了本实验条件下适宜的操作条件 .
The empirical models were established to describe the character of electrodialyzer when the wastewater of L -glutamic acid was separated by electrodialysis.The effects of several factors on the electrodialyzer's equipment and process performance were studied.The appropriate operation conditions were obtained.
出处
《膜科学与技术》
CAS
CSCD
北大核心
2002年第4期30-34,共5页
Membrane Science and Technology