摘要 目前,国际上对X射线空气比释动能基准的研究最高只达到400 kV,对于更高能量的X射线尚未建立相应基准。本文对自建立的250~450 kV X射线空气比释动能结果的不确定度进行了分析,分别得到了物理常数、有效测量体积、定位距离、电流测量、温度、气压、修正因子的不确定度。最终得到250~450 kV X射线空气比释动能结果的相对合成标准不确定度为0.31%,扩展不确定度为0.62%(k=2),其中不确定度来源中最大的2个量为电离功和修正因子,满足X射线空气比释动能复现的要求。 At present,the international research on the X ray air kinetic energy standard is only up to 400 kV,however for higher energy X ray,the corresponding standard has not been established. In this paper,we analyze the uncertainty of the air kinetic energy of self derived 250-450 kV X ray,and get the uncertainties of physical constants, effective measurement volume, positioning distance, current measurement,temperature,air pressure and correction factor respectively. What's more,we also get the uncertainty of the relative synthetic standard of the 250-450 kV X-ray air kerma is 0.31% and the uncertainty of development is 0. 62%(k = 2). The leading two values of the source of uncertainty are the ionization work and correction factor,which are meeting the requirements of the reappearance of X ray air kinetic energy.
作者 王波 任世伟 吴金杰 杜海燕 王继 WANG Bo;REN Shi-wei;WU Jin-jie;DU Hai-yan;WANG Ji(Hebei University of Science and Technology, Shijiazhuang 050000, China;National Institute of Metrology, Beijing 100029, China;Chengdu University of Technology, Chengdu, Sichuan 610059, China)
出处 《核电子学与探测技术》 北大核心 2017年第10期1027-1033,共7页 Nuclear Electronics & Detection Technology
基金 环境水平X射线空气比释动能测量方法研究 25-AKY1707
关键词 高能X射线 空气比释动能 不确定度 电离功 修正因子 High energy X-ray Air kinetic energy uncertainty Ionization work Correction factor
  • 相关文献

参考文献5

二级参考文献20

  • 1Rogers DWO,Bielajew AF.Wall attenuation and scatter corrections for ion chambers:measurements versus calculations.Phys Med Biol,1990,35:1065-1078.
  • 2Rogers DWO,Bielajew AF,Nahum AE.Ion chamber response and Awall correction factors in a ^60 Co beam by Monte Carlo simulation.Phys Med Biol,1985,30:429-443.
  • 3Bielajew AF.Correction factors for thick-walled ionization chambers in point-source photon beams.Phys Med Biol,1990,35:501-516.
  • 4Bielajew AF.On the technique of extrapolation to obtain wall correction factors for ion chambers irradiated by photon beams.Med Phys,1990,17:583-587.
  • 5Bielajew AF,Rogers DWO.Implications of new correction factors on primary air kerma standards in ^60Co beams.Phys Med Biol,1992,37:1283-1291.
  • 6Rogers DWO,Treurniet J.Monte carlo calculated wall and axial nonuniformity corrections for primary standards of air kerma.NRCC Report PIRS-663,1999.
  • 7Laitano RF,Toni MP,Pimpinella M,et al.Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in ^60Co Gamma Beams.Phys Med Biol,2002,47:2411-2431.
  • 8Allisy-Roberts PJ,Kessler C,Bums DT,et al.Comparison of the air kerma standards of the NIM and the BIPM ^60 Co γ rays.Draft Rapport BIPM-01/C,2001.
  • 9Wyckolf MO.Measurement of Cobalt-60 and Cesium-137 gamma rays with a free-air chamber.J Rrs Nat Bus Stand(US),1960,64C:87.
  • 10Shortt KR,Rass CK.The Canadian ^60Co exposure standard.NRC Report PIRS-0052,1986.