期刊文献+

近视眼患者配戴硬性透气性接触镜后残余像差对视觉质量的影响

Effect of residual aberration on visual quality after wearing rigid gas permeable contact lens in patients with myopia
暂未订购
导出
摘要 目的对近视眼患者配戴硬性透气性接触镜(RGPCL)后残余像差对视觉质量的影响进行分析。方法近视眼患者46例(87只眼),均配戴RGPCL进行视力矫正。配戴3个月内,采用自适应光学系统在4 mm直径人工瞳孔下测量和矫正RGPCL配戴眼的残余像差,同时对2、4、8、16、32cpd五个空间频率下MTF值、CSF值等指标进行统计分析,并评价配戴RGPCL后残余像差对视觉质量的影响。结果与配戴RGPCL残余像差矫正前相比,矫正后患者近视眼总像差RMS值、总低阶像差RMS值、总高阶像差RMS值到明显降低,差异具有统计学意义(P<0.05)。且配戴RGPCL残余像差矫正后近视眼在各个空间频率下的MTF值均有明显提高,差异具有统计学意义(P<0.05)。但残余像差矫正前后CSF值比较,差异无统计学意义(P>0.05)。结论硬性透气性接触镜在4 mm瞳孔直径下通过自适应光学系统矫正可以减小残余像差,获得理想的视觉质量。 Objective To analyze the effect of residual aberration on visual quality after wearing rigid gas permeable contact lens (RGPCL) in patients with myopia.Methods A total of 46 patients (87 eyes)who aged 12 - 25 years received vision correction by wearing RGPLC.Within 3 months after wearing,residual aberration measurement and correction of wearing RGPCL were performed using adaptive optics system at artificial pupil diameter of 4 mm,modulation transfer function (MTF) and contrast sensitivity function (CSF)were statistically analyzed under 5 spatial frequencies (2,4,8,16 and 32 cpd) at the same time.The effect of residual aberration on visual quality after wearing RGPCL was evaluated.Results The root mean square (RMS) of total aberration,total lower-order aberration and total higher-order aberration decreased significantly in the myopic eyes of patients compared to the values before correction with RGPCL.MTF of the myopic eyes under each spatial frequency increased significantly after correction with RGPCL (P〈0.05).There was no significant difference between CSF before and after residual aberration correction (P〉0.05).Conclusion RGPCL can reduce the residual aberration and can achieve satisfied visual quality by adaptive optical system correction at pupil diameter of 4 mm.
作者 林洁
出处 《微创医学》 2017年第5期622-624,共3页 Journal of Minimally Invasive Medicine
关键词 近视眼 硬性透气性接触镜 残余像差 视觉影响 Myopia Rigid air permeable contact lens Residual aberration Vision effect
  • 相关文献

参考文献6

二级参考文献62

  • 1钟兴武,龚向明,杨晓,戴祖优,魏玲,李树兴.Rose K硬透气性接触镜矫治圆锥角膜的临床观察[J].中国实用眼科杂志,2005,23(2):182-184. 被引量:26
  • 2褚仁远,戴锦晖,周行涛.要视力,更要视觉质量[J].中国眼耳鼻喉科杂志,2006,6(2):72-73. 被引量:15
  • 3程振英,褚仁远,周行涛.准分子激光原位角膜磨镶术治疗近视后眼高阶像差变化的研究[J].中华眼科杂志,2006,42(9):772-776. 被引量:34
  • 4Chemyak DA. Cyclotoraional eye motion occurring between wavefront measurement and refractive surgery [ J ]. J Cataract Refract Surg ,2004,30 ( 3 ) :633-638.
  • 5Ciccio AE, Durrie DS, Stahl JE, Schwendeman F. Ocular cyclotorsion during customized laser ablation [ J ]. J Refract Surg , 2005, 21 (6) :S772-774.
  • 6Chernyak DA. Iris-based cyclotorsional image alignment method for wavefront registration [ J ]. IEEE Trans Biomed Eng, 2005, 52(12) :2032-2040.
  • 7Chemyak DA. Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery[J]. J Cataract Refract Surg, 2004,30 ( 3 ) : 633 -668.
  • 8Swami AU, Steinert RE, Osborne WE, White AA. Rotational malposition during laser in situ keratomileusis [ J ]. Am J Ophthalmoi,2002,133 (4) :561-562.
  • 9Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Liorente L, Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing [ J ]. Invest Ophthalmol Vis Sci, 2001,42 ( 6 ) : 1396- 1403.
  • 10张琼,谢培英.透气性硬性接触镜用于圆锥角膜的矫正技术[J].中国老年学杂志,2011,24(31):313-315.

共引文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部