摘要
针对黔东电厂锅炉电除尘器运行中芒刺线频繁断裂,造成对应电场跳闸的故障进行了全面深入的分析,并在机组等级检修中采取简单高效的治理措施后,锅炉电除尘器从2015年机组运行中跳闸15次以上,下降至2016年的0次,最终彻底杜绝了该异常跳闸事件的发生,确保了该厂锅炉电除尘器的安全高效运行,为机组环保达标排放奠定了坚实基础。
Aim to barbed wires frequently break in the operation of boiler electrostatic precipitator of Qiandong power plant, a comprehensive and in-depth analysis was made on the fault of the causing corresponding electric field trip, and the simple and efficient control measures were taken in the unit grade maintenance, Boiler precipitator tripping times in the operation from 2015 trip more than 15 times, fell to zero in 2016, And finally eliminate the abnormal events of the trip completely, ensure safety and efficient operation of boiler precipitator in power plant, which laid a solid foundation for the environmental standards discharge.
作者
黄书芳
廖新强
Huang Shufang Liao Xinqiang(Guizhou qiandong electric power co. ,Ltd, Kaili 557702 Guizhou, chin)
出处
《贵州电力技术》
2017年第7期15-18,18,共4页
Guizhou Electric Power Technology
关键词
电除尘器
故障
原因
措施
electrostatic precipitator
fault cause
measures