期刊文献+

Trace analysis of off-flavor/odor compounds in water using liquid-liquid microextraction coupled with gas chromatography--positive chemical ionization-tandem mass spectrometry 被引量:5

Trace analysis of off-flavor/odor compounds in water using liquid-liquid microextraction coupled with gas chromatography--positive chemical ionization-tandem mass spectrometry
原文传递
导出
摘要 A rapid, inexpensive and laboratory friendly method was developed for analysis of off-flavor/odor compounds in fresh and salt water using gas chromatography with chemical ionization-tandem mass spectrometry. Off-flavor/odor compounds, included geosmin, 2- methylisobomeol (MIB), 2-isobutyl-3-methyoxypyrazine (IBMP), and 2-isopropyl-3-methoxypyrazine (IPMP). Using this method, a single sample can be extracted within minutes using only 1 mL of organic solvent. The ion transitions for IPMP, IBMP, MIB, and geosmin were 153 〉 121, 167 〉 125, 152 〉 95, and 165 〉 109, respectively. The linearity of this method for analyzing MIB ranged from 4 to 200ng·L^-1, and from 0.8 to 200ng·L^-1 for the other analytes. Method recoveries ranged from 97% to 111% and percent relative standard deviations ranged from 3% to 9%, indicating that the method is accurate, precise, and reliable. A rapid, inexpensive and laboratory friendly method was developed for analysis of off-flavor/odor compounds in fresh and salt water using gas chromatography with chemical ionization-tandem mass spectrometry. Off-flavor/odor compounds, included geosmin, 2- methylisobomeol (MIB), 2-isobutyl-3-methyoxypyrazine (IBMP), and 2-isopropyl-3-methoxypyrazine (IPMP). Using this method, a single sample can be extracted within minutes using only 1 mL of organic solvent. The ion transitions for IPMP, IBMP, MIB, and geosmin were 153 〉 121, 167 〉 125, 152 〉 95, and 165 〉 109, respectively. The linearity of this method for analyzing MIB ranged from 4 to 200ng·L^-1, and from 0.8 to 200ng·L^-1 for the other analytes. Method recoveries ranged from 97% to 111% and percent relative standard deviations ranged from 3% to 9%, indicating that the method is accurate, precise, and reliable.
出处 《Frontiers of Environmental Science & Engineering》 CSCD 2016年第3期477-481,共5页 环境科学与工程前沿(英文)
关键词 off-flavor/odor compounds liquid-liquid microextraction gas chromatography-tandem mass spectrometry off-flavor/odor compounds, liquid-liquid microextraction, gas chromatography-tandem mass spectrometry
  • 相关文献

参考文献1

共引文献6

同被引文献68

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部