地热热泵系统负荷调节的理论与试验分析 被引量:4

THEORY AND EXPERIMENT EVALUATION ABOUT LOAD ADJUSTMENT OF GEOTHERMAL HEAT PUMP SYSTEM
在线阅读 下载PDF
导出
摘要 为了解决地热热泵系统输出能量和用户需求能量之间的平衡问题,就必须选择出适宜的能量调节方式并加以研究。首先,对现有的几种能量调节方式进行了比较,发现了适宜的调控方式;然后,在小型地热热泵系统上进行了变频试验研究,频率变化范围为30~55Hz;最后,得出了系统各主要参数随频率的变化规律。此结论可以在制定地热热泵系统能量输出的调节策略中起到一定的指导作用。 In order to match the export capacity of geothermal heat pump system (GHPS) and the actual load, selection of suitable adjustment mode for GHPS and the influence of such mode on cycling parameters of GHPS are researched. Firstly, some adjustment modes are compared and it is found that the mode of import frequency conversion of compressor is better than others in GHPS. Secondly, experiments on a GHPS are done, with the frequencies changing from 30 Hz to 55 Hz. Lastly, based on the analysis of experimental data, the relationships between the compressor frequency and other important parameters are given, which may be helpful to adjust GHPS' export capacity.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2002年第8期100-104,共5页 Journal of Mechanical Engineering
基金 国家科技部'九五'重点攻关课题(98-A17-05-02)
关键词 地热热泵 负荷调节 频率变化 试验研究 Geothermal heat pump Capacity adjustment Frequency conversion Experimental research
  • 相关文献

参考文献5

  • 1[1]Domijan A,Embriz-Santander E.Measurement of electrical power inputs to variable-speed motors and their solid-state power converters.ASHRAE Trans.,1993,99(1):241~258
  • 2[2]Zubair S M,Habel V.Compressor capacity modulation schemes.Heating, Piping,Air Conditioning,1989 (1):135~143
  • 3[3]Tassou S A,Qureshi T Q.Comparative performance evaluation of positive displaycement compressors in variable-speed refrigeration applications.Int.J.Refrig., 1998,212(1):29~41
  • 4[4]Cooper W D.The use of mixed refrigerants in air-to-air heat pumps.ASHRAE Trans.,1992,part 2:320~325
  • 5[5]VaKi H B.New concept in capacity modulation using non-azeotropic mixtures.General Electric Reports,1983,83:212