摘要 岩土热响应试验测试技术始于20世纪80年代,最初在欧美一些发达国家得到深入的研究和应用。2009年,我国在原国家标准GB50366-2005《地源热泵系统工程技术规范》的基础上,增加补充了岩土热响应试验测试的相关内容。时隔6年,该项测试技术在我国得到广泛推广和应用,相关科研院所也就测试设备和测试方法展开深入的研究和讨论。本文以2009年版《规范》为核心,纵观国内与国外,就该测试技术展开比对分析,为促进地源热泵系统更加规范、健康的发展提供参考。 The study and development of rock-soil thermalresponsetestwasinitiated in EuropeandAmerican in 1980s, In 2009,the methods ofthermal responsetest and related content were appended to the original "Technical CodeforGround-Source Heat PumpSystem"(GB50366- 2005)n our nation. Over the past 6 years,the application of TRThasbeenspreadwidely, andthedevelopmenthasbeen studieddeeply, andthemethod hasbeendiscussed broadly. Thispaperpointingatthe"Code",throughoutthecountryand abroad, concerns about thecomparisen and analysis of the testing method, for the more standardized and healthy developmentofGround-SourceHeatPumpSystem.
出处 《供热制冷》 2015年第7期60-63,共4页 Heating & Refrigeration
基金 "十二五"国家科技支撑项目"可再生能源在建筑中一体化及高效应用关键技术研究与示范"课题资助(项目编号:2014BAJ01B00)
关键词 测试 岩土热响应试验 比对分析 Test, Rock-soil thermal response test,Comparison andanalysis
  • 相关文献

参考文献6

  • 1Mogensen P.(1983). Fluid to Duct Wall Heat Transfer in Duct System Heat Storagem ProG Int. Con On Subsurface Heat Storage in Theory and Practice. Stockholm,Sweden,June 6-8,1983,p.652-657.
  • 2朱清宇,徐伟,沈亮.《地源热泵系统工程技术规范》修订要点解读[J].暖通空调,2010,40(7):40-43. 被引量:11
  • 3方肇洪,刁乃仁,曾和义.地热换热器的传热分析[J].工程热物理学报,2004,25(4):685-687. 被引量:22
  • 4Austin IIL A.,C. YavuzturK J. D. Spitler.(2000). Development of an In-Situ System for Measuring Ground Thermal Propertiem ASHRAE Transactionm 106(1)65-379.
  • 5Gehlin S. and B. Nordell.(1998). Thermal Response Tests of Boreholes Results from In-Situ Measurements. Proc. Second International Stockton Geothermal Confer- ence. 15-16 March 1998. Richard Stockton College of New Jersey,Pomona,USA.
  • 6Katsura,T. Nagano,K. Okawada,T. & Hori S.(2009): Investigation of Ground Water Flow Effect on the Ther- mal Response Test Result.-Proceedings of 11 th Energy Conservation Thermal Energy Storage Conference Effs- tock 200 Stockholm.

二级参考文献15

共引文献31

同被引文献27

  • 1王沣浩,颜亮,冯琛琛,王新轲.地源热泵岩土热响应测试影响因素分析[J].制冷技术,2012,32(2):1-5. 被引量:9
  • 2于明志,彭晓峰,方肇洪,李晓东.地下岩土热物性及地下水渗流速度确定[J].应用基础与工程科学学报,2007,15(2):196-202. 被引量:17
  • 3宗显雷.地热桩基的分析与设计[D].北京:清华大学,2010.
  • 4李新.能量桩的传热研究和工程应用[D].济南:山东建筑大学,2008.
  • 5Eklof C,Gehlin S.A mobile equipment for thermal response test[D].Sweden:Lulea University of Technology,1996.
  • 6Sanner B,Karytsas C,Mendrinos D,et al.Current status of ground source heat pumps and underground thermal energy storage in Europe[J].Geothermics,2003,32:579-588.
  • 7Smith M,Perry R.In-situ testing and thermal conductivity testing[R].Oklahoma:Oklahoma State University,1999.
  • 8Nagano K.TRT by using a hot wire cable[R].Bologna:IEA,2009.
  • 9Fujii H,Okubo H,Nishi K,et al.An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers[J].Geothermics,2009,38:399-406.
  • 10Fujii H,Okubo H,Itoi R.Thermal response tests using optical fiber thermometers[J].Geothermal Resources Council Transactions,2006,30:545-551.

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部