期刊文献+

X-STOP棘突间撑开器治疗椎间盘突出症的临床疗效

Clinical outcomes of X-STOP for herniated intervertebral disc disease
暂未订购
导出
摘要 目的:研究通过运用X-STOP棘间撑开器治疗腰椎间盘突出症的临床疗效。方法:选择2008年1月-2011年12月期间,我院采用国产X-STOP棘突间撑开器治疗腰椎间盘突出症患者18例,其中男8例,女10例。观察并记录患者术前、术后6个月及末次随访时腰腿痛情况、手术节段椎间高度变化及椎间盘Pfirrmann评分。结果:平均随访(4.7±1.1)年。随访期间无1例患者复发。术后患者腰腿痛明显缓解,末次随访ODI评分、手术节段椎间高度及椎间盘Pfirrmann评分与术前比较,差异有统计学意义(P〈0.05);终板夹角术前与末次随访比较,差异无统计学意义(P〉0.05)。结论:X-STOP棘突间撑开器治疗腰椎间盘突出症疗效满意,并且能有效预防病变节段椎间盘的再次退变。 Objective: To evaluate the clinical effects by applying interspinous spacer( X-STOP) implantation to treatment of herniated intervertebral disc.Methods: A total of 18 cases( 8 males,10 females) with herniated disk undergone treatment with domestic X-STOP were included from January 2008 to December 2011. The clinical data were retrospectively examined regarding low back pain scores maintained before operation,6 months after operation and final follow-up as well as restoration of intervertebral disc height,lumbar movement range and Pfirrmann grading on MRI. Results: No relapse occurred in all patients in the follow-up periods( mean 4. 7 ± 1. 1years). The difference was significant in terms of back pain relief,final scores by Oswestry disability index( ODI),restoration of intervertebral disc height and scoring by Pfirrmann grading system as compared with preoperative observations( P〈0. 05),yet the vertebral endplate angle measured before operation remained no significance with the findings by final follow-up( P〉0. 05). Conclusion: X-STOP interspinous implant can be effective for lumbar intervertebral disc and prevent the diseased disc from re-degeneration.
出处 《皖南医学院学报》 CAS 2015年第3期222-225,共4页 Journal of Wannan Medical College
基金 安徽省教育厅自然科学研究基金重点项目(KJ2013A253)
关键词 棘突间撑开器 腰椎间盘突出症 临床疗效 interspinous spacer herniated intervertebral disc clinical effect
  • 相关文献

参考文献14

  • 1Putzier M,Strube P,Funk JF,et al.Allogenic versus autologous cancellous bone in lumbar segmental spondylodesis:a randomized prospective study[J].Eur Spine J,2009,18(5):687-695.
  • 2Sears WR,Serqides IG,Kazemi N,et al.Incidence and prevalence of surgery at segments adjacent to a previous posterior lumbar arthrodesis[J].Spine J,2011,11(1):11-20.
  • 3Zucherman JF,Hsu KY,Hartien CA,et al.A multicenter,pr-ospective,randomized evaluating the X STOP interspinous process decompression system for the treatment of neurogenic intermittent claudication:two-year follow-up results[J].Spine,2005,30(12):1351-1358.
  • 4Shabat S,Miller LE,Block JE,et al.Minimally invasive treatment of lumbar spinal stenosis with a novel interspinous spacer[J].Clin Interv Aging,2011,6:227-233.
  • 5Puzzilli F,Gazzeri R,Galarza M,et al.Interspinous spacer decompression(X-STOP)for lumbar spinal stenosis and degenerative disk disease:a multicenter study with a minimum 3-year follow-up[J].Clin Neurol Neurosurg,2014,124:166-174.
  • 6Kuchta J,Sobottke R,Eysel P,et al.Two-year results of interspinous spacer(X-Stop)implantation in 175 patients with neurologic intermittent claudication due tu lumbar spinal stenosis[J].Eur Spine J,2009,18(6):823-829.
  • 7Wu AM,Zhou Y,Li QL,et al.Interspinous spacer versus traditional decompressive surgery for lumbar spinal stenosis:a systematic review and meta-analysis[J].PLo S One,2014,9(5):e97142.
  • 8Siddiqui M,Smith FW,Wardlaw D.One-year results of X-Stop interspinous implant for the treatment of lumbar spinal stenosis[J].Spine,2007,32(12):1345-1348.
  • 9Zaveri GR,Mehta SS.Surgical treatment of lumbar tuberculous spondylodiscitis by transforaminal lumbar interbody fusion(TLIF)and posterior instrumentation[J].J Spinal Disord Tech,2009,22(4):257-262.
  • 10苏晋,赵文志,陈秉智,李斌,何盛为,方旭.椎板不同切除范围对腰椎生物力学影响的有限元分析[J].生物医学工程学杂志,2012,29(3):465-469. 被引量:22

二级参考文献14

  • 1AMUNDSEN T, WEBER H, LILLEAS F. Lumbar spinal stenosis. Clinical and radiologic feature[J']. Spine (Phila Pa 1976), 1995, 20(10): 1178-1186.
  • 2SCHOFFERMAN J, REYNOLDS J, HERZOG R, et al. Failed back surgery: etiology and diagnostic evaluation[J]. Spine (Phila Pa 1976), 2003, 3(5): 400-403.
  • 3WILKE H, NEEF P, HINZ B, et al. Intradiscal pressure together with anthropometric data--a data set for the validation of models[J]. Clin Biomech , 2001, 16 (Suppl 1): S111- S126.
  • 4LU Y M, HUTTON W C,GHARPURAY V M. Do bending, twisting,and diurnal fluid changes in the disc affect the propensity to prolapse A viscoelastic finite element model [J].Spine (Phila Pa 1976) , 1996, 21(22): 2570-2579.
  • 5BOWDEN A E, GUERIN H L, VILLARRAGA M L, et al. Quality of motion eonsiderations in numerical analysis of mo- tion restoring implants of the spine[J]. Clinical Biomeehanics, 2008, 23(5): 536-544.
  • 6AHMAD F, KOICHI S, GOEL V K, et al. Biomeehanical rationale of ossification of the secondary ossification center on apophyseal bony ring fracture: a biomechanical study [J]. Clinical Biomechanics, 2007, 22(10): 1063-1067.
  • 7ANTONIUS R, NAGANANDA K, BURRA J. Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine:a finite element analysis[J].Eur Spine J, 2007(16) : 1223-1231.
  • 8POLIKEIT A, NOLTE L P, FERGUSON S J. The effect of cement augmentation on the load transfer in an osteoporotie functional spinal unit, finite-element analysis [J]. Spine, 2003, 28(10): 991-996.
  • 9TROPIANO P, THOLLON L, ARNOUX P J, et al. Using a finite clement model to evaluate human injuries application to the HUMOS model in whiplash situation[J]. Spine (Phila Pa 1976), 2004, 29(16): 1709-1716.
  • 10ZANDER T, ROHLMANN A, CALISSE J, et al. Estimation of muscle forces in the lumbar spine during upper-body inclination[J]. Clin Biomech ( Bristol, Avon), 2001, 16 (Suppl 1) : S73-S80.

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部