期刊文献+

ICP-AES法同时测定二氧化铀中痕量钾、钠 被引量:1

Determination of trace potassium and sodium in uranium dioxide by ICP-AES
在线阅读 下载PDF
导出
摘要 采用TBP萃淋树脂,在酸性介质中使铀与待测元素定量分离,用ICP-AES法同时测定二氧化铀中钾、钠的含量.当试样平行测定6次时,钾、钠测定结果相对标准偏差分别为5.8%和6.4%,加标回收率分别为93.5%~104.3%和92.3%~102.8%.称样质量为0.5g时,方法的测定下限钾、钠分别为0.11×10-6和0.07×10-6.该方法满足二氧化铀中痕量钾、钠的分析要求. In acid medium uranium is separated from impurities by TBP Eluex resin, and potassium and sodium in uranium dioxide were determined simultaneously by ICP-AES method. When the sam- ple is measured 6 times in parallel, the measurement result of relative standard deviations is 5.8 % for potassium, and 6.4% for sodium as well as recovery is 93.5% -107.0% for potassium, and 91.5- 102.8% for sodium. If sample mass is 0.5 g, and 0.07 × 10-6 for sodium respectively. The potassium and sodium in uranium dioxide. lower limit of the method is 0.11 × 10-6 for potassium method can meet requirements of determination of trace
机构地区 中核
出处 《铀矿冶》 CAS 2014年第4期223-226,共4页 Uranium Mining and Metallurgy
关键词 二氧化铀 ICP-AES TBP萃淋树脂 uranium dioxide potassium sodium TBP Eluex resin ICP-AES
  • 相关文献

参考文献4

  • 1GB/T13370-1992二氧化铀粉末和芯块中锂、钠、钾、铯的测定原子吸收分光光度法/火焰发射光谱法[S].北京:中国标准出版社,1992.
  • 2EJ/T11021999天然二氧化铀中银等24种杂质元素的测定ICP-AES法[S].北京:核工业标准化研究所,1999.
  • 3李洪,李强,杨箭,贺艳红.ICP-AES法测定天然二氧化铀中锂、硼、锆、铌[J].铀矿冶,2011,30(3):157-161. 被引量:7
  • 4王清良.铀提取工艺学[M].哈尔滨:哈尔滨工程大学出版社,2009:254.

二级参考文献4

  • 1EJ/T989-1996天然二氧化铀技术条件[s].北京:核工业标准化研究所,1996.
  • 2GB/T11839-2008二氧化铀芯块中硼的测定:姜黄素萃取光度法[s].北京:中国标准出版社,1989.
  • 3GB/T13370-1992二氧化铀粉末和芯块中锂,钠,钾,铯的测定:原子吸收分光光度法/火焰发射光谱法[s].北京:中国标准出版社,1992.
  • 4EJ/T1102-1999天然二氧化铀中银等二十四种杂质元素的测定:ICP-AES法[S].北京:核工业标准化研究所,1999.