期刊文献+

Calibration method for electrode gains in an axially symmetric stripline BPM 被引量:1

Calibration method for electrode gains in an axially symmetric stripline BPM
在线阅读 下载PDF
导出
摘要 The four electrodes in the stripline beam position monitor(BPM) for Hefei Light Source(HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best.The electrode gains of two stripline BPMs(HLS II SR-BD-STLB1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15. The four electrodes in the stripline beam position monitor (BPM) for Hefei Light Source (HLS II) storage ring are of axially symmetric type. We have derived a new calibration method of electrode gains for this type stripline BPM. The gain fit error of different data grids was analyzed, and the ±5 mm by ±5 mm grid is the best. The electrode gains of two stripline BPMs (HLS II SR-BD-STLB 1 and HLS II SR-BD-STLB2) were obtained based on offline calibrated data. The results show that data after fitting gains are improved, with the electrode gains being between 0.94 and 1.15.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2014年第5期6-9,共4页 核技术(英文)
基金 Supported by the Natural Science Foundation of China(Nos.11175173,11375178 and 11005105)
关键词 条形电极 轴向对称 校准方法 BPM 带状线 增益 数据网格 HLS Stripline beam position monitor, Electrode gain, Axially symmetric, Calibration
  • 相关文献

参考文献7

  • 1Rubin D L, Billing M, Meller R, et al. Phys Rev Spec Top-AC, 2010, 13: 092802.
  • 2Miller R H, Clendenin J E, James M B, et al. Nonintercepting Emittance Monitor, SLAC-PUB-3186, 1983.
  • 3Fang J, Sun B G, Lu P, et al. Atom Energ Sci Technol, 2011, 44: 511-516. (in Chinese).
  • 4Olmos A, P6rez F, Rehm G. Matlab Code for BPM Button Geometry Computation. Proceedings of DIPAC 2007,186-188.Venice, Itally, 2007.
  • 5Russell J S, Gilpatrick D J, Power J F, et al. Characterization of beam position monitor for measurement of second moment. Proceedings of PAC 1995, 2580-2582. Dallas, USA, 1995.
  • 6Wu F F, Zhou Z R, Sun B G, et al. High Power Laser Part Beam, 2011, 23: 2971-2975. (in Chinese).
  • 7Ma T J, Yang Y L, Sun B G, et al. Nucl Sci Tech, 2012, 23: 261-266.