期刊文献+

320排CT容积扫描法与螺旋扫描法在低心率冠状动脉成像中的对比研究 被引量:5

Low heart rate coronary CT angiography with 320-row detector:a comparison of volume scan and helical scan
原文传递
导出
摘要 目的比较320排CT容积扫描法(volume法)与螺旋扫描法(helical法)在低心率冠状动脉成像中的应用价值。方法 128例患者分为两组:容积扫描组(n=72)和螺旋扫描组(n=56),分别采用CT容积扫描法及螺旋扫描法进行冠状动脉成像扫描(检查时患者心率均低于65次/min),对比分析两组患者的图像质量、辐射剂量及对比剂用量。结果容积扫描组和螺旋扫描组患者升主动脉根部CT值分别为(492.08±58.51)HU、(522.72±56.91)HU,图像噪声分别为(19.64±3.51)HU、(22.66±5.33)HU,差异无统计学意义;两组冠状动脉节段优秀率分别为97.5%(632/648)、96.8%(488/504),合格率分别为99.7%(646/648)、99.2%(500/504),差异无统计学意义。容积扫描组、螺旋扫描组有效辐射剂量分别为(3.21±0.23)mSv、(13.27±2.39)mSv,差异有统计学意义(P〈0.001);对比剂用量分别为50~60mL、80~90mL。结论低心率时320排CT容积扫描法与螺旋扫描法均可获得满意的冠脉图像,但容积扫描法辐射剂量更低、造影剂用量更少,具有一定优势。 Objective To compare the values of volume scan and helical scan in low heart rate coronary CT angiography.Methods Coronary CT angiography was done with 320-row detector in 128 patients.The patients were assigned to two groups:Group 1(n=72)undergoing volume scan and Group 2(n=56)undergoing helical scan.The heart rates of patients were lower than 65/min during examination.The image quality,radiation dose,and amount of contrast were compared between two groups.Results The ascending aorta root CT values of group 1 and group 2 were(492.08±58.51)HU and(522.72±56.91)HU,and the image noise of the two groups were(19.64±3.51)HU and(22.66±5.33)HU,respectively.The excellent rates of coronary artery image quality in group 1 and group 2 were 97.5%(632/648)and 96.8%(488/504),and the pass rates were 99.7%(646/648)and 99.2%(500/504),respectively.There were no significant differences concerning image noise,excellent rates of image,or pass rates of image between the two groups(P0.05).The effective radiation doses were significantly lower in group 1 compared with group 2([3.21±0.23]mSv vs[13.27±2.39]mSv,P0.001).The amounts of contrast in group 1 and group 2 were 50-60mL and 80-90mL,respectively.Conclusion Image quality of coronary CT angiography obtained with volume scan and helical scan can both meet the requirement for clinical diagnosis,but compared with the helical scan,volume scan shows an advantage as it needs lower radiation dose and less contrast.
出处 《第二军医大学学报》 CAS CSCD 北大核心 2014年第7期796-799,共4页 Academic Journal of Second Military Medical University
关键词 锥束计算机体层摄影术 螺旋计算机体层摄影术 冠状血管造影术 低心率 辐射剂量 cone-beam computed tomography spiral computed tomography coronary angiography low heart rate radiation dosage
  • 相关文献

参考文献4

二级参考文献15

共引文献179

同被引文献42

  • 1Martinek M,Nesser HJ,Aichinger J,et al.Accuracyof intergration of multislice computed tomographyimaging into three-dimensional electroanatomicmapping for real-time guided radiofrequencyablation of left atrial fibrillation-influence ofheart rhythm and radiofrequency lesions[J],JInterv Card Electrophysiol, 2006,17(2) : 85-92.
  • 2Cleland JG,Daubert JC,Erdmann E,et al.Theeffect of cardiac resynchronization on morbidityand mortality in heart failure[J].N Engl JMed,2005,352(15): 1539-1549.
  • 3Mlynarski R,Sosnowski M,Wlodyka A,et al.A user-friendly method of cardiac venoussystem visualization in 64-slice computedtomography[J]. Pacing Clin Electrophysiol,2009,32(3):323-329.
  • 4Jongbloed MR,Lamb HJ,Bax JJ,et al.Nonin-vasive visualization of the cardiac venous systemusing multislice computed tomography[J]. J AmColl Cardiol, 2005,45(5) : 749-753.
  • 5Gene B,Solak A,Sahin N,et al.Assessment ofthe coronary venous system by using cardicCT[J].Diagn Interv Radiol,2013,19(4):286-293.
  • 6Torres FS,Crean AM,Nguyen ET,et al.Abolitionof respiratory-motion artifact in computedtomography coronary angiography with ultrafastexaminations:a comparison between 64-row and320-row multidetector scanners[J].Can AssocRadiol J,2010,61(1):5-12.
  • 7Dewey M,Zimmermann E,Deissenrieder F,et al.Noninvasive coronary angiography by 320-row computed tomography with lower radiationexposure and maintained diagnostic accuracy :comparison of results with cardiac catheterizationin head-to-head pilot investigation[J]. Circulation,2009,120(10):867-875.
  • 8Defranee T,Dubois E,Gebow D,et al.Helicalprospective ECG-gating in cardiac computedtomography : radiation dose and image quality[J].Int J Cardiovasc Imaging,2010,26(1):99-107.
  • 9Mlynarski R,Sosnowski M,Wlodyka A,et al.Optimal image reconstruction intervals fornoninvasive visualization of the cardiac venoussystem with a 64-slice computed tomography [J].Int J Cardiovasc Imaging,2009,25(6):635-641.
  • 10Schart SM, Bromberger-Barnea B , PermuttS.Distribution of coronary venous flow[J].JAppl Physiol, 1971,30(5) : 657-662.

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部