摘要
许多医院洁净手术室的设计在很大程度上受到工业洁净技术的影响,片面强调净化级别、依赖大风量或滥用层流技术等,造成洁净手术部投资和运行费用高昂。从污染控制思路出发,介绍洁净手术部净化空调系统的设计理念与方法,认为净化只是一种保障手段,无菌程度才是控制的目的和结果的体现;应该强调手术室细菌控制的综合措施,强调全过程控制以及完善的保证体系。
Many existing operating rooms were designed to a great extent following the ways of industrial cleaning room designing such as seeking improperly high degrees of cleanliness, high air changes and laminar air flow technique, resulting in too high investment and operating costs. Discusses on the basis of contamination control the design concepts and methodology and emphasises comprehensive bacteria control during the whole process only using cleaning technology to ensure the bioclean environment aiming at prevention of cross infection risks.
出处
《暖通空调》
北大核心
2001年第5期7-12,共6页
Heating Ventilating & Air Conditioning
关键词
空气洁净
手术室
通风
空调