摘要
从理论上分析了两级爆磁压缩发生器运行时的电压分布 ,从实验上用 SF6作为绝缘介质解决了爆磁压缩装置运行时高压击穿的难题。对爆磁压缩装置的研究和类似高压绝缘的问题具有借鉴意义。
The voltage distribution of the two class explosively driven magnetic flux compression generator (EMCG) is discussed theoretically. The difficult problem about the high voltage breakdown is resolved by using SF 6 when the EMCG is operating. This will be used for reference in other EMCG research and the similar high voltage insulation problem.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
2001年第6期9-9,19,共2页
High Voltage Engineering
基金
国家 8 6 3项目资助
关键词
爆磁压缩发生器
高压绝缘
实验
六氟化硫
explosively driven magnetic flux compression generator SF 6 high voltage insulation