血氧饱和度和呼气末二氧化碳分压监测阻塞性睡眠呼吸暂停综合征的对比研究 被引量:1

Clinical comparative study on monitoring of nocturcal SaO_2 and PetCO_2 in obstructive sleep apnea syndrome
暂未订购
导出
摘要 目的 监测阻塞性睡眠呼吸暂停综合征 (OSAS)患者的夜间血氧饱和度 (SaO2 )和呼气末二氧化碳分压 (PetCO2 ) ,以比较其临床价值。方法 对 2 5例OSAS患者同步进行多导睡眠图、SaO2 和PetCO2 监测 ,并对有关SaO2 和PetCO2 的指标进行对比。结果 伴有SaO2 下降的呼吸紊乱总频率 ( 75.2± 2 7.8) %较伴有PetCO2 上升的呼吸紊乱总频率 ( 2 7.2± 1 7.4) %明显高 (P <0 .0 0 1 )。平均SaO2 、最低SaO2 和伴氧饱和度下降≥ 4%的平均SaO2 与AI、AHI呈负相关 ;T 90 %与AI、AHI呈正相关。夜间平均PetCO2 和最高PetCO2 与AI、HI、AHI比较均无显著相关性。结论 夜间氧饱和度监测对OSAS筛选具有明确临床意义 ;PetCO2 监测对判断OSAS病情有价值 ;但PetCO2 不及SaO2 敏感 ,需大样本多中心进一步研究。 Objective To investigate the clinical significance of SaO 2 and PetCO 2 to detect obstructive sleep apnea syndrome (OSAS). Methods Polysomnography (PSG), pulse oximeter and capnography monitoring were performed simultaneously in 25 patients. The parameters related with SaO 2 and PetCO 2 were compared. Results The frequence of respiratory disturbance with desaturation was significantly higher than that with PetCO 2 ascending [(75.2±27.8)% vs (27.2±17.4)%, P<0.001].The mean and lowest nocturnal SaO 2, mean SaO 2 with desaturation value higher than 4% were negatively correlated with apnea index (AI) and apnea hypopnea index (AHI). T 90% was positively correlated with AI and AHI. The mean and the highest nocturnal PetCO 2 weren't significantly correlated with AI and AHI. Conclusion Nocturnal SaO 2 monitoring is a simple and valuable method for the diagnosis of OSAS. PetCO 2 monitoring can provide useful information about patients' condition. Its validity and its sensitivity for the detection of OSAS will be subject of a subsequent study.
作者 刘升明
出处 《临床内科杂志》 CAS 北大核心 2001年第5期347-349,共3页 Journal of Clinical Internal Medicine
  • 相关文献

参考文献2

  • 1[1]Crocker BD, Olson LG, Saunders NA, et al. Estimation of the probebility of disturbed breathing during sleep before a sleep study. Am Rev Respir Dis, 1990,142(1): 14-18.
  • 2[2]Schaefer T, Burmann-Urbanek M, Glaser S, et al. Capnography in sleep medicine, a multicenter study. Somnologie, 1999, 3(1): 3-13.

同被引文献14

  • 1丁平,朱慕云,卞京文.呼气末二氧化碳分压的连续监测在机械通气中的应用价值[J].临床荟萃,2004,19(22):1264-1264. 被引量:1
  • 2张战军,李祥军,刘小军,朱保国.呼气末二氧化碳监测在全麻插管中的应用[J].中国误诊学杂志,2005,5(3):567-568. 被引量:1
  • 3刘锦铭,高蓓兰,江平,吴文,王英敏,郑卫,朱东,杨文兰,蔡映云.肺栓塞患者肺内死腔、肺内分流及气体交换的研究[J].中华结核和呼吸杂志,2005,28(11):802-803. 被引量:7
  • 4Barnes TA, Macdonald D, Nolan J, et al. Cardiopulmonary resuscitation and emergency cardiovascular care. Airway devices.Ann Emerg Med,2001,37(4 Suppl) :S145-S151.
  • 5Fletcher R,Jonson B, Cumming G, et al. The concept of deadspace with special reference to the single breath test for carbon dioxide. Br J Anaesth,1981,53:77-88.
  • 6Domsky M, Wilson RF, Heins J. Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcome:prognosis and capnography. Crit Care Med, 1995,23 : 1497-1503.
  • 7Mikelson KS,Sterner SP, Ruiz E. Exhaled PCO2 as a predictor of endotracheal tube placement (abstract). Ann Emerg Med ,1986,15 :657.
  • 8Garnett AR, Gervin CA, Gervin AS. Capnographic waveforms in esophageal intubation: effect of carbonated beverages. Ann Emerg Med, 1989,18 : 387 -390.
  • 9Schafer T. Method for measuring respiration in sleep:capnography for determining ventilation. Biomed Tech (Berl) ,2003,48:170-175.
  • 10Eriksson L, Wollmer P, Olsson CG, et al. Diagnosis of pulmonary embolism based upon alveolar dead space analysis. Chest, 1989,96:357 -362.

引证文献1

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部