期刊文献+

准确测定湿雪的含水率──秋田谷式含水率计测量值的气温订正 被引量:3

Refining Measured Water Content Values of Wet Snow──Correcting Errors Arising from Air Temperature in the Measurement by Akitaya Calorimeter
在线阅读 下载PDF
导出
摘要 在应用秋田谷式含水率计测量湿雪含水率的过程中,雪样被短时间暴露在通常为正温的环境中产生融化,从而带来量测值的误差.通过试验,建立标准操作时间,然后利用大量的野外雪水分离及含水率量测资料,得出气温对含水率测定值影响的定量关系.测定值的气温(T,℃)订正值为-0.37T(T≥0). This paper deals with the quantitative impact of air temperature on the measured water content value of wet snow by Akitaya calorimeter. Based on the pre-experiments, a set of operating standards was determined. Upon the standards, large amounts of snow(grains)-water separation and snow water content measurement were conducted in the field. By regression, it is found that a correct water content value is obtained by subtracting 0.37T (T:air temperature,≥0) from the measured value.
出处 《晓庄学院自然科学学报》 EI CAS 北大核心 2001年第2期80-83,共4页 Journal of Natural Science of Hunan Normal University
基金 日本文部省资助项目 晓庄学院科研基金资助项目
关键词 湿雪 含水率 含水率计 秋田谷 测量值 气温订正 Calorimetry Regression analysis Temperature measurement