期刊文献+

致密多晶羟基磷灰石微粒人工骨的血液相容性 被引量:5

Bloodcompatibility of Dense Polycrystalline Hydroxyapatite Particles as Bone Substitute
暂未订购
导出
摘要 对用致密多晶羟基磷灰石微粒人工骨作整复的20例患者,在手术植入材料前后分别检测病员血清中 IgG、IgA、IgM、C_3、C_4、CIC 水平,结果表明,术前术后各项检测指标的差别无显著性,说明该人工骨材料植入体内后不影响机体免疫功能,不改变机体正常的免疫状况,具有很好的血液相容性。 In order to understand the bloodcompatibility of dense polycrystalline hydroxyap-atite particles,the levels of immunoglobulin(IgG,IgA,IgM),complements(C_3,C_4)and circulate immune complex(CIC)of the patients who received surgical treatmentwith dense polycrystalline hydroxyapatite particles were measured before operationand post-operation.No significant changes were detected.The results indicate that theimmunologic function and status of these patients were not affected and altered bythe materials.There were no immunologic reaction elicited by the materials.The ma-terials have a good bloodcompatibility.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 1991年第1期25-27,共3页 West China Journal of Stomatology
  • 相关文献

同被引文献11

  • 1孙铁航.尖周外科概况[J].国外医学.口腔医学分册,1985,4:205-205.
  • 2王大章 李声伟.用致密多晶羟基磷灰石微粒人工骨行牙槽嵴再造术初步报告[J].中华口腔医学杂志,1989,5:290-290.
  • 3M. Bornapour,M. Celikin,M. Cerruti,M. Pekguleryuz.Magnesium implant alloy with low levels of strontium and calcium: The third element effect and phase selection improve bio-corrosion resistance and mechanical performance[J]. Materials Science & Engineering C . 2014
  • 4Wang Y M,Guo J W,Shao Z K,Zhuang J P,Jin M S,Wu C J,Wei D Q,Zhou Y.Ametasilicate-based ceramic coating formed on magnesium alloy by microarc oxidationand its corrosion in simulated body fluid. Surface and Coatings Technology . 2013
  • 5Merritt K,Brown S A,Sharkey N A.The binding of metal salts and corrosion products to cells and proteins in vitro. Journal of Biomechanics . 1984
  • 6曾荣昌,孔令鸿,陈君,崔洪芝,刘成龙.医用镁合金表面改性研究进展[J].中国有色金属学报,2011,21(1):35-43. 被引量:48
  • 7张雅静,张丹,习小慧,贾海龙.AZ31仿生沉积羟基磷灰石涂层的研究[J].东北大学学报(自然科学版),2011,32(11):1611-1614. 被引量:13
  • 8彭友霖,周丽丽,周艳红.镁合金作为生物医用植入材料的临床应用[J].中国组织工程研究与临床康复,2011,15(42):7923-7926. 被引量:16
  • 9高亚丽,接勐,张海波.医用镁合金表面激光重熔羟基磷灰石涂层[J].材料热处理学报,2012,33(9):117-121. 被引量:5
  • 10李涛,张海龙,何勇,张金玲,王西涛.生物医用镁合金研究进展[J].功能材料,2013,44(20):2913-2918. 被引量:27