摘要
本文提出了一新型的实验室装置——球柱吸收塔,该吸收装置具有传质特性稳定,实验重现性好的特点。基于Danckwerts表面更新传质模型,作者提出了一修正模型,该模型能较好地解释球柱吸收塔的传质现象。
A new laboratory gas liquid mass transfer equipment, sphero-cylindrical column, has been developed and its mass transfer behavior has been studied. The authors proposed a modified surface renewal mass transfer model, with which the mass transfer charateristies of sphero-cylindrical column could be better explained. The calculated results of the modified model and experimental data were in fair agreement.