摘要 驱动马达为小汽轮机的引风机与常规电动机驱动的引风机相比,其启动和并联具有特殊性。通过分析探讨可知,在引风机进口加补气门可保证单台引风机安全启动,在引风机进出口加烟气循环联络烟道可保证两台风机安全并联运行。 The start and operation in parallel of indraft fan driven by turbine is particular, which is different from fan driven by electric motor. An air-supplying gate is set in the inlet of indraft fan can ensure the safe start of a single set of fan. And a measure is introduced to assure the stable run in parallel of two sets of fans by means of adding a gas-circuiting conduit between the two fans.
机构地区 成都电力机械厂
出处 《风机技术》 2014年第3期75-78,共4页 Chinese Journal of Turbomachinery
关键词 汽动引风机 单机启动 并联运行 烟气循环 indraft fan driven by turbine start of a single set of fan run in parallel circulating of flue gas
  • 相关文献

参考文献11

二级参考文献27

  • 1李庆军,侯国忠,黄晓波.浅谈多风井多风机分区并联通风[J].煤炭技术,2005,24(2):67-68. 被引量:15
  • 2沈士一,庄贺庆,康松,等.汽轮机原理[M].北京:水利电力出版社,1991.
  • 3中国华电工程有限公司.烟风与煤粉制备系统设备[M].北京:中国电力出版社,2009.
  • 4GB50660--2011,大中型火力发电厂设计规范[S].
  • 5GB13223-201l,火电厂大气污染物排放标准[S].
  • 6郭立君.泵与风机[M].北京:中国电力出版社,2004.
  • 7西安热工研究院编著.发电技术节能降耗技术.中国电力出版社,2010.
  • 8何川,郭立君.泵与风机[M].第四版.北京:中国电力出版社,2007.
  • 9华能国际电力股份有限公司.电站锅炉烟风煤粉管道设计优化与风机节能研究(报告)[R].2011.
  • 10武瑞林.煤气鼓风机的喘振现象及其预防[J].燃料与化工,1997,28(5):281-283. 被引量:4