摘要
目的:检测两种隐形眼镜片对护理液中薄荷醇的吸收和释放程度。方法:样品经C18键和硅胶固相萃取后,采用毛细管气相色谱柱法分离和FID检测器检测。结果:J1102809和G1105599隐形眼镜单位质量(mg)干镜片吸收和释放薄荷醇分别为0.118 2、0.120 5μg和0.004 3、0.005 6μg。结论:隐形眼镜片对护理液中薄荷醇的吸收和释放均为微量,可安全使用。
Objective: In functional care solution , the menthol absorption and release of contact lenses was studied.Methods:The sample was concentrated by C18 column solid-phase extraction, and analyzed by capillary gas chromatography and FID detector .Results: The menthol absorption and release of per unit weight ( mg ) J1102809 and G1105599 contact lenses were 0.118 2μg、0.120 5μg,and 0.004 3μg、0.005 6μg, respectively. Conclusion:The results show that menthol in functional care solution might be safe for use taking the trace quantity of menthol into account .
出处
《东南大学学报(医学版)》
CAS
2014年第2期143-146,共4页
Journal of Southeast University(Medical Science Edition)
基金
国家自然科学基金资助项目(81172721)
关键词
隐形眼镜片
护理液
薄荷醇
吸收
释放
contact lenses
functional care solution
menthol
absorption
release