期刊文献+

分光光度法测定消毒剂中的甲醛 被引量:21

Measurement of formaldehyde in disinfectant with spectrophotometry
暂未订购
导出
摘要 用乙酰丙酮分光光度法测定消毒剂中的甲醛。结果表明 ,甲醛的线性范围在 0~ 10μg/ml之间 ,检测下限为 0 .0 8μg/ml,不同浓度样品的精密度小于 3.9% ,加标回收率为 10 0 .2 %~ 10 8.2 % ,与容量法相比较差异无显著性。与其它分光光度法相比 ,该法具有操作简便、重现性好、灵敏度高、选择性好等优点 ,适合测定用容量法有干扰时消毒剂中的甲醛。 Formaldehyde in disinfectant was measured by acetylacetone spectrophotometry. The regression equation was linear when the formaldehyde concentration was smaller than 10μg/ml. The detection limit was 0 08μg/ml. The accuracy was less than 3 9% and the recovery varied between 100 2%—108 2% for formaldehyde disinfectant with different concentration, which was similar to titrimetry. It was demonstrated that the method was simple, reproducible, sensitive ,precise and accurate, making it important for assay of formaldehyde in disinfectant when disturbance caused titrimetry unavailable.
出处 《卫生研究》 CAS CSCD 北大核心 2001年第1期18-19,共2页 Journal of Hygiene Research
关键词 消毒剂 甲醛 分光光度法 测定 disinfectant formaldehyde
  • 相关文献

参考文献8

  • 1中华人民共和国卫生部.中华人民共和国卫生部消毒技术规范(第1分册)第3版[M].北京:中华人民共和国卫生部,1999.74.
  • 2《水质分析大全》编写组.水质分析大全[M].重庆:科学技术文献出版社重庆分社,1989.355.
  • 3中华人民共和国卫生部 卫生法制与监督司.化妆品卫生规范[M].北京:中华人民共和国卫生部,1999.165-166.
  • 4中华人民共和国卫生部卫生法制与监督司,化妆品卫生规范,1999年,165页
  • 5中华人民共和国卫生部,中华人民共和国卫生部消毒技术规范 (第1分册 )(第3版),1999年,74页
  • 6《水质分析大全》编写组,水质分析大全,1989年,355页
  • 7中国预防医学中心卫生所,大气污染监测方法,1984年,557页
  • 8GB/T16 12 9 1995 居住区大气中甲醛卫生检验标准方法 AHMT分光光度法