摘要
介绍了BCL60 7离心压缩机节能改造的三种方案和节能改造的原则。压缩机节能改造不仅要满足管路系统流量、压头的需要 ,在确定降速幅度时还要进行喘振的校核。另外 ,还给出了降速后压缩机的节能量的计算公式。
Three energy saving scheme,as well as energy saving principle of BCL607 was introduced.Energy saving of centrifugal compressor not only satisfies the flux and pressure of pipeline system,but also verifies vibration when choosing the extent of lowering speed.Calculating formula of energy saving in BCL607 Centrifugal Compressor was presented.
出处
《节能技术》
CAS
2000年第5期31-33,共3页
Energy Conservation Technology
关键词
离心压缩机
调速
节能
Centrifugal compressor
Speed adjusting
Energy saving