期刊文献+

含氟人工唾液对选择性激光熔积钴铬合金耐腐蚀性的影响 被引量:1

Effects of different fluorine-containing oral artificial saliva solution on anti-corrosion behavior of selective laser melting cobalt-chromium alloy
暂未订购
导出
摘要 目的观察含氟人工唾液对选择性激光熔积技术(SLM)制作的钴铬合金耐腐蚀性的影响。方法将具有相同成分的钴铬合金粉末和金属块,分别运用SLM技术(SLM组)和铸造工艺(对照组)制作试件,每组40个。分别在pH为5.0和2.5以及模拟口腔含氟0、0.05%、0.10%和0.20%的条件下,将试件置于Fusayam人工唾液中浸泡24 h。采用极化曲线Tafel外延法求得两组试样的极化阻力Rp值,比较两组试件的耐腐蚀性。结果 pH值为5.0时,在含氟0和0.05%的条件下,两组间Rp值比较差异无统计学意义(P>0.05);而在含氟0.1%和0.2%的条件下,SLM组的Rp值显著大于对照组(P<0.05)。当pH为2.5时,在含氟0、0.05%、0.10%和0.20%的条件下,SLM组的Rp值均显著大于对照组(P<0.05)。结论氟化物能影响钴铬合金的耐腐蚀性能,SLM钴铬合金的耐腐蚀性优于铸造钴铬合金。 Objective To evaluate the effects of different fluoride-containing artificial saliva solution on the corrosion of the dental cobalt-chromium (Co-Cr) alloy fabricated by selective laser melting (SLM). Methods The study involved two groups, each group has 40 cylinder specimens and all specimens were fabricated by the same Co-Cr alloy. One group adopted SLM, while the other group used the cast method. Under conditions of two different pHs (2.5 and 5.0) and four different fluoride-containing artificial saliva solution concentration (0, 0. 05%, 0. 1%, and 0.2% ), polarization curve tests were performed to compare the anti-corrosion ability of two groups. Results For pH of 5. 0 (fluoride- containing artificial saliva solution concentrations were 0 and 0. 05% ), differences of Rp values between two groups were not statistically significant (P 〉 0. 05). For pH of 5. 0 (fluoride-containing artificial saliva solution concentration were 0. 1% and 0. 2% ) and pH of 2.5 (fluoride-containing artificial saliva solution concentration were 0, 0. 05%, 0. 1%, and 0. 2% ), the Rp value of SLM specimens were significantly higher than those of the cast ones (P 〈 0. 05). Conclusion Fluorine can affect the anti-corrosion ability of Co-Cr alloy. SLM specimens exhibited a significantly better anti-corrosion ability than cast ones.
出处 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2014年第3期314-317,328,共5页 Journal of Shanghai Jiao tong University:Medical Science
基金 上海市科委资助项目(12441903001 13140902701)~~
关键词 选择性激光熔积技术 钴铬合金 氟化物 耐腐蚀性 selective laser melting Cobalt-chromium alloy fluoride anti-corrosion behavior
  • 相关文献

参考文献12

二级参考文献48

  • 1汤秀春,李四群,李欣,李志安.氟化物控释装置对钴铬合金腐蚀性的实验研究[J].口腔医学研究,2005,21(1):38-40. 被引量:6
  • 2李四群,程祥荣,钱法汤.氟化物控释装置在可摘局部义齿中应用的初步研究[J].中华口腔医学杂志,1994,29(4):238-241. 被引量:15
  • 3宋继武,牟月照.齿科铸造合金的电化学腐蚀研究进展[J].口腔颌面修复学杂志,2006,7(2):146-148. 被引量:12
  • 4Takemoto S,Hattori M,Yoshinari M,et al.Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride[J].Dent Mater J,2004,23(3):379-386.
  • 5Kang EH,Park SB,Kim HI,et al.Corrosion-related changes on Ti-based orthodontic brackets in acetic NaF solutions:surface morphology,microhardness,and element release[J].Dent Mater,2008,27(4):555-560.
  • 6Takemoto S, Hattori M, Yoshinari M, et al. Corrosion behavior and surface characterization of Ti-2~Cr alloy in a solution containing fluoride[J]. Dent Mater J, 2004, 23(3):379-386.
  • 7王宏伟.表面粗糙度的测量与数据处理.科技信息,2009,(35):728-728.
  • 8Willems G, Lambrechts P, Braem M, et al. Composite resins in the 21st century[J]. Quintessence Int, 1993, 24(9):641-658.
  • 9Quirynen M, Bollen CM, Papaioannou W, et al. The influence of titanium abutment surface roughness on plaque accumulation and gingivitis: Short-term observations[J]. Int J Oral Maxillofac Im- plants, 1996, 11 (2) : 169-178.
  • 10Cai Z, Vermilyea SG, Brantley WA. In vitro corrosion resistance of high-palladium dental casting alloys[J]. Dent Mater, 1999, 15 (3) : 202-210.