期刊文献+

350MW燃煤机组加装MGGH系统设计方案的制定 被引量:8

在线阅读 下载PDF
导出
摘要 从350MW机组实际情况出发,结合内外部条件与烟气情况,制定了MGGH的加装方案。结果表明,加装MGGH系统后,可将排烟温度由158℃降低到95℃,除尘器入口烟气体积流量由1 874 000 m3/h降低到1 600 000 m3/h,结合高频电源改造后,可使电除尘器烟尘排放浓度由86 mg/Nm3降低到30 mg/Nm3;还可将脱硫系统后的烟气温度由30℃提高到95℃,有效缓解烟道及烟囱的腐蚀。 The actual situation of 350MW units as a starting point, combined with the existing condition of the internal and external conditions and gas conditions, MGGH installation programmes have been developed. The Results show that after the installation of MGGH system,the exhaust gas temperature can he reduced from 158℃ to 95℃, the inlet flue gas volume flow of ESP can be reduced from 1 874 000 m3/h to 1 600 000m3/h, combined with high frequency power supply,the dust emission concentration of ESP can be reduced from 86 mg/Nm3 to 30 mg/Nma;the temperature of the flue gas after desulfurization system can be raised from 30 ℃ to 95 ℃, effectively mitigates corrosion of the flue and chimney.
出处 《环境保护与循环经济》 2014年第2期42-47,共6页 environmental protection and circular economy
关键词 350MW燃煤机组 MGGH 设计方案 350MW coal-fired units MGGH design program