Systematic review of mini-implant displacement under orthodontic loading 被引量:3

Systematic review of mini-implant displacement under orthodontic loading
暂未订购
导出
摘要 A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displacement immediately straight after loading and secondary displacement over time. A systematic review was performed to investigate primary and secondary displacement. The amount and type of displacement were recorded. A total of 27 studies were included. Sixteen in vitro studies or studies using finite element analysis addressed primary displacement, and nine clinical studies and two animal studies addressed secondary displacement. Significant primary displacement was detected (6.4-24.4 μm) for relevant orthodontic forces (0.5-2.5 N). The mean secondary displacement ranged from 0 to 2.7 mm for entire mini-implants, The maximum values for each clinical study ranged from 1.0 to 4.1 mm for the head, 1.0 to 1.5 for the body and 1,0 to 1.92 mm for the tail part. The most frequent type of movement was controlled tipping or bodily movement. Primary displacement did not reach a clinically significant level. However, clinicians can expect relevant secondary displacement in the direction of force. Consequently, decentralized insertion within the inter-radicular space, away from force direction, might be favourable. More evidence is needed to provide quantitative recommendations. A growing number of studies have reported that mini-implants do not remain in exactly the same position during treatment, although they remain stable. The aim of this review was to collect data regarding primary displacement immediately straight after loading and secondary displacement over time. A systematic review was performed to investigate primary and secondary displacement. The amount and type of displacement were recorded. A total of 27 studies were included. Sixteen in vitro studies or studies using finite element analysis addressed primary displacement, and nine clinical studies and two animal studies addressed secondary displacement. Significant primary displacement was detected (6.4-24.4 μm) for relevant orthodontic forces (0.5-2.5 N). The mean secondary displacement ranged from 0 to 2.7 mm for entire mini-implants, The maximum values for each clinical study ranged from 1.0 to 4.1 mm for the head, 1.0 to 1.5 for the body and 1,0 to 1.92 mm for the tail part. The most frequent type of movement was controlled tipping or bodily movement. Primary displacement did not reach a clinically significant level. However, clinicians can expect relevant secondary displacement in the direction of force. Consequently, decentralized insertion within the inter-radicular space, away from force direction, might be favourable. More evidence is needed to provide quantitative recommendations.
出处 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第1期1-6,共6页 国际口腔科学杂志(英文版)
关键词 DISPLACEMENT MIGRATION MINI-IMPLANT MINISCREW ORTHODONTICS skeletal anchorage displacement migration mini-implant miniscrew orthodontics skeletal anchorage
  • 相关文献

参考文献64

  • 1Fortini A, Lupoli M, Giuntoli F et al. Dentoskeletal effects induced by rapid molar distalization with the first class appliance. Am J Orthod Dentofacial Orthop 2004, 125(6), 697-704, discussion 704-705.
  • 2Kokich VG, Mathews DP. Surgical and orthodontic management of impacted teeth. Dent Clin North Am 1993, 37(2): 181-204.
  • 3Kircelli BH, Pektas ZO, Uckan S. Orthopedic protraction with skeletal anchorage in a patient with maxillary hypoplasia and hypodontia, Angle Orthod 2006, 76(1): 156- 163.
  • 4Henry PJ. Clinical experiences with dental implants, AdvDentRes 1999, 13: 147- 152.
  • 5Cornelis MA, de Clerck HJ. Maxillary molar distalization with miniplates assessed on digital models: a prospective clinical trial. Am J Orthod Dentofacial Orthop 2007, 132(3): 373-377.
  • 6Sugawara J, Kanzaki R, Takahashi Iet al. Distal movement of maxillary molars in nongrowing patients with the skeletal anchorage system. Am J Orthod Dentofacial Orthop 2006, 129(6): 723-733.
  • 7Costa A, Raffainl M, Melsen B. Miniscrews as orthodontic anchorage: a preliminary report. Int J Adult Orthodon OrthoEnath Sure 1998, 13(3): 201-209.
  • 8Melsen B, Costa A. Immediate loading of implants used for orthodontic anchorage. Clin Orthod Res 2000, 3(1): 23-28.
  • 9Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod1997 , 31(11): 7 63- 767.
  • 10Yao CC, Lai EH, Chang JZ et al. Comparison of treatment outcomes between skeletal anchorage and extraoral anchorage in adults with maxillary dentoalveolar protrusion. Am J Orthod Dentofacial Orthop 2008, 134(5): 615-624.

同被引文献30

引证文献3

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部