期刊文献+

高植入扭力对微型种植体-骨界面愈合的组织学影响 被引量:10

Effect of excessive insertion torque on the implant-bone interface observed by histology
暂未订购
导出
摘要 目的:探讨高植入扭力对种植体-骨界面组织愈合的影响。方法:将36枚微型种植体以(14±1)Ncm及(11±1)Ncm的扭力植入4只Beagle犬的下颌牙槽骨,观察7 d及28 d的组织学、组织形态测量学及扫描电镜变化。结果:14 Ncm组植入后7 d界面密骨质有重度微损伤,28 d骨界面仍有许多碎骨屑。而11 Ncm组7 d骨质轻度微损伤,28 d骨愈合良好。2组种植体-骨结合率(BIC)无显著差异(P>0.05),7 d时,2组种植体-骨密度(BD)值差异无统计学意义(P>0.05),但28 d时,11 Ncm组BD值明显高于14 Ncm组(P<0.05)。结论:适度扭力植入种植体的骨界面损伤小、愈合快,而过高植入扭力可造成骨界面严重微损伤,影响骨组织愈合。 Objective: To study interfacial bone healing after mini-implants inserted by different torques.Methods: 36 mini-implants were placed in the mandibular alveolar bone of 4 adult male Beagle dogs.(14±1) Ncm and(11±1) Ncm insertion torque were applied in the two groups respectively at the time of fixture placement.Bone tissue responses were evaluated by histological analysis at 7 and 28 days after implant placement respectively.Results: The histomorphologic observation showed that in the 14 Ncm group 7 days after implantation,bone around the implants had severe micro-injury.28 days after implantation,there were still many bone chips in bone interface.In the 11 Ncm group 7 days after implantation,bone micro-damage was mild,bone healed well after 28 days.The implant-to-bone contact ratio(%) was not significantly different(P〉0.05).The implant-to-bone density(BD) value of the two groups was not significantly different 7 days after implantation(P〉0.05),but after 28 days,the BD of 11 Ncm group was significantly higher than that in 14 Ncm group(P〈0.05).Conclusion: Moderate insertion torque is in favor of peri-implant bone healing,and excessive torque can cause interfacial bone micro-damage.
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2012年第4期430-434,共5页 Journal of Practical Stomatology
基金 河北省科技支撑资助项目(编号:08276101D-4)
关键词 微型种植体 微损伤 植入扭力 骨整合 Mini- implant Micro- damage Insertion torque Osseointegration
  • 相关文献

参考文献12

  • 1闫翔,赵计林,苏寒,陆苇,赵丹,邹颖.微种植体支抗在压低成年人伸长磨牙中的应用[J].实用口腔医学杂志,2010,26(3):397-398. 被引量:10
  • 2史聪翀,张晓蓉,黄家昕,邓怡.颧骨种植体支抗后牵引猴上颌骨颅颌面三维形态学研究[J].实用口腔医学杂志,2011,27(3):311-315. 被引量:2
  • 3Ottoni J, Oliveira Z, Mansini R. Correlation between plance- ment torque and survival of single-tooth implants [ J ]. lnt J Oral Maxillofae implants, 2005,20( 5 ) : 769 - 776.
  • 4Motoyoshi M, Hirabavashi M, Uemura M, et al. Recona- mended placement torque when tightening an orthodontic mini-implant[J]. Clin Oral Implants Res, 2006, 17 ( 1 ) : 109 - 114.
  • 5Buehter A, Kleinheinz J,Wiesmann HP, et al. Interface re-action at dental implants inserted in condensed bone [ J ]. C l in Oral Implants Res, 2005,16 ( 5 ) :509 - 517.
  • 6Nergiz NA, Nergiz I, Schulz, et al. Reactions of peri-im- plant tissues to continuous loading of osseointegrated im- plants [ J ]. Am J Orthod Dentofacial Orthop, 1998,114 ( 3 ) : 292 - :298.
  • 7Cheng SJ, Tseng IY, Lee JJ,et al. A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage [ J ]. Int J Oral Maxillofac Im- plants, 2004,19( 1 ) :100 - 106.
  • 8Wihnes B, Drescher D. Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage [J]. Int J Oral Maxillofac Surg, 2011,40 (7) :697 - 703.
  • 9Chaddad K, Ferreira AFH, Geurs N, et al. Influence of sur face characteristics on survival rates of mini-implants[ J ]. Angle Orthodontist, 2008,78 ( 1 ) : 107 - 113.
  • 10Wawrzinek C, Sommer T, Fischer-Brandies H. Microdam- age in cortical bone clue to tile overtightening of orthodontic microscrews[J]. Orofac Orthop, 2008,69(2) : 121 - 134.

二级参考文献15

  • 1张强,赵志河,王军,赵美英.后牵引矫形力的方向对上颌腭部位移及应力分布的影响[J].四川大学学报(医学版),2004,35(5):680-682. 被引量:3
  • 2寻春雷,曾祥龙,王兴.自攻型微钛钉种植体增强磨牙支抗的临床应用研究[J].中华口腔医学杂志,2004,39(6):505-508. 被引量:72
  • 3徐芸 ,小山勋男 ,傅民魁 ,高国杰 ,张晓蓉 ,尹康 .种植体支抗向后牵引上颌骨动物模型的建立[J].口腔正畸学,2005,12(2):77-80. 被引量:19
  • 4Roberts WE,Smith RK,Mozsary PG,et al.Osseous adaptation to continuous loading of rigid endosseous implants[J].Am J Orthod,1984,86(2):95-111.
  • 5Kato S,Kato M.Intrusion of molars with implants as anchorage:A report of two cases[J].Clin Inplant Dent Relat Res,2006,8(2):100-106.
  • 6Salem OH,MaCarthy TS.Modified transpalatal bar for maxillary molar instrusion[J].J Clin Orthod,2005,39(11):668-671.
  • 7Hideboh CE, Vanniet MW, Knapp RH, et al. Validation study of skull three dimensi-onal computerized tomography measurements[J]. Am J phys Anthropol, 1990, 82 (3) : 283 - 294.
  • 8McCance AM, Moss JP, Fright WR, et al. A three-dimensional analysis of bone and soft tissue to bone ratio of movements in 17 Skeletal II patients following orthognathicsurgery [J]. Eur J Orthod, 1993, 15(2) :97-106.
  • 9Kragt G, Duterloo HS, Ten Bosch JJ. The initial reaction of a macerated human skull caused by orthodontic cervical trac- tion determined by laser metrology [J]. Am J Orthod, 1982, 81(1) :49 -56.
  • 10Tanne K, Miyasaka J, Yamagata T, et al. Three-dimensional model of the human craniofaeial sketeton: Method and preliminary results using finite element analysis[J]. J Biomech Eng, 1988,10( 3 ) :246 - 252.

共引文献10

同被引文献67

引证文献10

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部