期刊文献+

可植入式接触镜植入术后拱高及对比敏感度的临床观察 被引量:2

Clinical observation of vault and contrast sensitivity after ICL implantation
暂未订购
导出
摘要 目的:观察可植入式接触镜(implantation collamer lens,ICL)植入术后拱高及对比敏感度的变化情况。方法:收集在我院植入ICL的高度近视患者15例30眼,年龄20~40(平均28.0)岁,术前屈光度等效球镜度数为-6.50^-22.50(平均-11.05±2.50)D。采用光学相干断层扫描仪分别检查术后6mo;1,2,3a的拱高情况,以及对比敏感度检测仪检查术后1,3a的对比敏感度情况。结果:患者术后6mo时拱高均值最大,以后每年下降,3a后拱高与术后6mo比较,拱高下降,差异具有统计学意义。对比敏感度术后1a与3a比较差异无统计学意义,并且均位于正常值内。结论:ICL植入术后拱高随着术后时间的延长而下降,对比敏感度却未见明显改变。二者更长期的改变有待进一步观察。 AIM: To evaluate the changes of vault and contrast sensitivity after implantable collamer lens ( ICL ) implantation in high myopia. METHODS: The clinical data of 15 patients ( 30 eyes ) were collected.The patients'average age was 28.0 years ( from 20 to 40 years ) .Preoperative spherical refraction was (-6.50 to -22.50)D (mean -11.05±2.50)D.The vault was measured with optical coherence topography (OCT), after operation 6mo, 1, 2, 3a; and the contrast sensitivity function was measured with vision testing instrument after operation 1 and 3a. RESULTS: The results revealed that the vault was decreased after operation 6mo which was the highest. There was statistical difference between 6mo and 3a. While the contrast sensitivity was no statistical difference after operation between 1a and 3a and was all in the normal value. CONCLUSION: The vault was decreased after ICL implantation in high myopia with years, but the contrast sensitivity was no obvious change. A long -time observation for the vault and contrast sensitivity should be performed.
出处 《国际眼科杂志》 CAS 2014年第3期529-531,共3页 International Eye Science
关键词 拱高 对比敏感度 可植入晶状体 vault contrast sensitivity implantation collamer lens
  • 相关文献

参考文献11

  • 1Emara B, Probst LE, Tingey DP, et al. Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 1998 ;24 ( 10 ) : 1320-1325 2.
  • 2Schmidinger G, Lackner B, Pieh S, et al. Long- term changes in posterior chamber phakic intraoeular collamer lens vaulting in myopic patients. Ophthalmology 2010 ; 117 (8) : 1506-1511 3.
  • 3Jones CE, Atchison DA, Pope JM. Change in lens dimensions and refractive index with age and accommodation. J Optom Vis Sci 2007;84 (10) 990-995 4.
  • 4Petternel V, K:ppl CM, Dejaco- Ruhswurrn I, et al. Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eye. Ophthalmology 2004 ; 111 (2) : 325-331 5.
  • 5Karniya K, Shimizu K, Komatsu M. Factors affecting vaulting after implantable collamer lens implantation. J Refract Surg 2009;25 (3) :259-264 6.
  • 6Sanders DR. Anterior subcapsular opacities and cataracts 5 years after surgery in the visian implantable collamer lens FDA trial. J Refract Surg 2008 ;24(6) :566-570 7.
  • 7Wooten BR, Renzi LM, Moore, et al . A practical method of measuring the human temporal contrast sensitity function. Biomed opt Exoress 2010 ; 1 ( 1 ) :47-58.
  • 8雷蕾,张建华,郑磊,高鹏,王倩,冯华章,樊琪.正视及低中度、高度近视人群明暗环境对比敏感度分析[J].眼科新进展,2008,28(8):604-606. 被引量:22
  • 9杨必,刘陇黔,叶健雄.人眼黄斑色素密度与对比敏感度功能的关系[J].眼视光学杂志,2007,9(6):398-401. 被引量:7
  • 10聂晓丽,刘苏冰,左志高,尹黎,马宁,江红玲.超高度近视患者ICL植入后对比敏感度及像差的变化[J].眼科新进展,2012,32(11):1054-1057. 被引量:10