大口径凸非球面反射镜检测补偿器的误差标定 被引量:2

Error Calibration of Compensator in Large Aperture Convex Aspheric Mirror Testing
原文传递
导出
摘要 大口径凸非球面反射镜的检测是非球面检测中的难题,而零位补偿检测方法是精确检测大口径凸非球面反射镜的有效检测方法之一,但是随着补偿器口径的增大,在补偿器的加工和装调中难免引入误差。文章针对与球面偏差不大的凸非球面反射镜补偿检测,提出了一种用标准球面在线标定补偿器误差的方法,并对一凸非球面补偿检测中的误差进行了标定,使用标定后的补偿器对该凸非球面反射镜进行了补偿检测,并对标定误差进行了分析,标定前补偿器误差方均根值(RMS)为0.097A(波长λ=632.8nm),标定后综合检测误差RMS值小于0.0046λ,满足该凸非球面反射镜设计精度要求。 Testing of the large-aperture convex aspheric mirror is a very difficult task in the aspherical testing. The null lens compensator is one of the efficient methods for testing the large-aperture convex aspheric mirrors. However, with the aperture increasing, some unavoidable errors are induced in the fabrication and adjustment of the compensator. In this paper, a method using a standard sphere mirror is proposed to calibrate the error of the compensator. The system error in the compensator is tested and calibrated. The calibrated compensator is used to measure the large-aperture aspheric mirror. The calibration error is also analyzed. The root-mean-square (RMS) error before calibration is 0. 097 2 (wavelength λ = 632.8 nm), which significantly deteriorates the testing calibration is smaller than 0. 0046λ, which satisfies the mirror. accuracy in the null lens testing. The final testing RMS error after designed precision requirement of the large-aperture convex aspheric
作者 张斌智 王旭
出处 《中国激光》 EI CAS CSCD 北大核心 2013年第B12期206-209,共4页 Chinese Journal of Lasers
基金 国家973计划(2011CB0132005)、国家自然科学基金重点项目(61036015)
关键词 测量 凸非球面反射镜检测 误差标定 标准球面 零位补偿 measurement convex aspheric mirror testing error calibration standard spherical surface null compensator
  • 相关文献

参考文献11

二级参考文献58

共引文献81

同被引文献18

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部