期刊文献+

玻碳电极碱性水溶液氧化测定碳水化合物的研究

Studies on Determination of Carbohydrate by Oxidation on Glassy Carbon Electrode in Basic Solutions
在线阅读 下载PDF
导出
摘要 将玻碳电极置于0.1或0.2mol/L NaOH溶液中,采用恒电位(0.75V vs SCE)或电位扫描(0~0.75 V)的方式氧化测定葡萄糖、蔗糖、果糖等碳水化合物,检测下限达1μg/mL,电极的重现性良好,使用寿命长,葡萄糖的检测范围为0.1~5×10^(16)mol/L.初步探讨了反应机理。 The determination of carbohydrate, such as glucose, fructose, maltose, lactose, sucrose, glycerol etc. was carried out with glassy carbon electrode by constant potential oxidation (0. 75 V vs. SCE) or potential sweep oxidation(0. 2-0. 75 V) in 0. 1 or 0. 2 mol/L NaOH solution. The lowest detection limit is 1 μg/mL, A better repeatability and long useful lifetime are obtained. The detection range of glucose is 0.1-5×10-6 mol/L. The response mechanism is discussed in this paper.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 1991年第10期1316-1319,共4页 Chemical Journal of Chinese Universities
关键词 葡萄糖 玻碳电极 电化学 Electrochemical oxygen evolution, Electrochemical oxidation, Glassy carbon electrode, Glucose, Carbohydrate