摘要
建立了用分光光度法测定CO助燃剂中铂含量的方法.在盐酸介质中,Pt(Ⅳ)被氯化亚锡溶液还原,生成黄色的亚氯铂酸(H2PtCl4),最大吸收波长位于403nm处.方法简单、快捷、准确,回收率在97%~103%之间,相对标准偏差小于2.0%.在优化的实验条件下,助燃剂中的常见元素对测定铂含量无干扰.
A method for the determination of platinum content in CO combustion improver using a spectrophotomeic method is described. In an HC1 medium, Pt( Ⅳ )was reduced by SnCI2 solution and formed a yellow color chloroplatious acid( H2PtCI4 ). The absorption maxima of which is at a wavelength of 403 nm. The method features simplicity,rapidness and accuracy, with a recovery in the range of 97% to 103% ,and the relative standard deviations were less than 2%. The common elements existed in the CO combustion improver do not interfere the determination of platinum under the optimized test conditions.
出处
《分析测试技术与仪器》
CAS
2013年第4期214-216,共3页
Analysis and Testing Technology and Instruments
关键词
助燃剂
铂
分光光度法
combustion improver
platinum
spectrophotornetry