摘要 研究多波长分光光度法对Fe、Cu、Cr、Ni 4种金属同时定量分析.考察了通常存在的Ca、Mg、Zn对测定的干扰,确定了4种金属的最佳吸收波长,并在特定波长下测定摩尔吸光系数,建立了完整的线性方程.采用本方法对配制的Fe、Cu、Cr、Ni混合溶液进行测定,验证其线性方程的准确性,结果表明其相对误差在±5%以内.考虑不同样品金属离子的含量不同,对多波长分光光度法进行了测定下限的研究.结果表明:采用本方法 Fe、Cu、Cr、Ni的测定下限分别为5×10-4mg/mL、1×10-3mg/mL、5×10-3mg/mL、5×10-3mg/mL,在此浓度以上的样品均可获得可靠的定量分析结果.最后对实际电镀污泥中Fe、Cu、Cr、Ni的含量进行测定,分析测定结果与原子吸收分光光度法是一致的. Through multi-wavelength spectrophotometry, the contents of four kinds of metal ions (Fe, Cu, Cr, Ni) can be determined simultaneously in this paper. The interferences of usually existing ions of Ca, Mg, Zn on measurement are discussed, and the best absorption wavelengths of the four metal ions are found out. The molar absorption coefficient under the specific wavelength is determined, and the complete linear equation is established. To verify the accuracy of the linear equations, the prepared mixed solution of Fe,Cu,Cr,Ni is measured by this method, and the result shows that the relative error can be controlled within ±5 %. Considering the content of metal ions can be varied in different realistic samples, the lower limit of this method was studied. The experimental result shows that the lower limit of Fe, Cu, Cr, Ni are 5×10-4 mg/mL, 1×10-3 mg/mL, 5×10-3 mg/mL, 5×10-3 mg/mL, respectively, and the reliable result of quantitative analysis can be obtained when the concentration of samples can exceed that. Finally, the content of Fe, Cu, Cr, Ni in electroplating sludge are measured, and the result is consistent with atomic absorption spectrophotometry.
出处 《有色金属科学与工程》 CAS 2013年第6期13-18,共6页 Nonferrous Metals Science and Engineering
基金 国家自然科学基金资助项目(51364014) 江西省教育厅科技资助项目(赣教高字[2011]号GJJ11458 GJJ11476 GJJ10157) 江西省科技厅科技资助项目(2013BBG70003)
关键词 多波长分光光度法 干扰分析 线性方程 测定 下限 multi-wavelength speetrophotometry interference analysis linear equation determination lower limit
  • 相关文献

参考文献20

  • 1王晓辉.化学计量学在我国的发展[J].中国石油和化工标准与质量,2012,32(6):31-31. 被引量:1
  • 2Pinto R C,Trygg J,Gottfries J.Advantages of orthogonal inspection in chemometrics[J].Journal of Chemometrics,2012,26(6): 231-235.
  • 3翟虎,陈小全,邵辉莹.多元校正-紫外分光光度法同时测定苯酚和间苯二酚[J].光谱实验室,2008,25(3):440-443. 被引量:7
  • 4夏立娅,吴广臣,王庭新.多波长K系数5-Br-PADAP分光光度法同时测定工业废水中铜(Ⅱ)、铁(Ⅲ)和铁(Ⅱ)的研究[J].冶金分析,2008,28(2):10-14. 被引量:3
  • 5Kumar R S,Pamireddy P,Emmadi C S.Simultaneous determination of naproxen sodium and pantoprazole sodium in bulk and pharmaceutical dosage form by validated ultra-violet spectrophotometric method[J].International Journal of Chemical and Analytical Science,2012,3(10): 1569-1572.
  • 6Ni Y,Zhang G,Kokotc S.Simultaneous spectrophotometric determination of maltol,ethyl maltol,vanillin and ethyl vanillin in foods by multivariate calibration and artificial neural networks[J].Food Chemistry,2005,89(3): 465-473.
  • 7方国桢,郭忠先.6种化学计量学法同时分光光度测定5组分的比较研究及食品分析[J].分析化学,1994,22(3):265-271. 被引量:21
  • 8García Fraga J M,Jiménez Abizanda A I,Jiménez Moreno F,et al.Simultaneous determination of amitriptyline,imipramine and perphenazine in pharmaceutical preparations and blood serum by multi-wavelength spectrophotometry[J].Analytica Chimica Acta,1991,252(1/2): 107-113.
  • 9Tam K Y,Takács-Novák K.Multi-wavelength spectrophotometric determination of acid dissociation constants: a validation study[J].Analytica Chimica Acta,2001,434(1):157-167.
  • 10华东理工大学分析化学考研组,四川大学工科化学基础课程教学基地.分析化学[M].6版.北京:高等教育出版社,2009.

二级参考文献101

共引文献164

同被引文献20

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部