摘要
为准确灵敏地分析土壤中低浓度滴滴涕及其衍生物(DDTs),以正己烷-丙酮(1:1,体积比)作为提取剂超声提取土壤中的DDTs,采用自主研发的四通道色谱分离仪对提取液进行分离,利用装有电子捕获检测器的气相色谱(GC/ECD)进行分析,探讨了不同层析柱填料和洗脱剂对6种DDTs目标物回收率的影响。结果表明,采用新型混合层析柱填料,以二氯甲烷-正己烷(4:1)作为洗脱剂,各目标物的超声提取回收率为83.5%~90.3%,方法的检出限为2.0~5.4 ng·g^(-1)。并对超声提取和索氏提取法的加标回收率进行了比较。
A new sample purification method was developed for the determination of low levels of DDTs in soils.The tested soil was extracted with a mixture of hexane-acetone(1∶1) by ultrasonic method.The soil extracts was purified with a patented four-channel purification chromatograph before analysis by gas chromatography with electron capture detector(GC/ECD).Effects of different column packs and elution solvents on recoveries of DDTs were investigated.The results showed that by using ultrasonic extraction,new mixed filling material for the chromatogram column and elution with dichloromethane-n-hexane(4∶1),the recoveries of DDTs were between 83.5% and 90.3%,and the method detection limits were between 2.0 ng?g-1 and 5.4 ng?g-1,implying that the method can be used for the determination of low levels of DDTs in soils.In addition,the spiked recoveries of DDTs based on the ultrasonic extraction and Soxhlet extraction were compared under the optimal purification conditions.The results showed that the recovery of the Soxhlet extraction method is higher than that of the ultrasonic extraction method,but the the former need consume more time.