期刊文献+

基于放疗中重复四维CT的食管癌大体肿瘤体积位移变化的比较研究 被引量:2

A comparative study of GTV displacements of primary thoracic esophageal carcinoma based on repeated 4DCT scans during radiotherapy
原文传递
导出
摘要 目的 基于重复四维CT (4DCT)模拟定位增强扫描探讨放疗中胸段食管癌原发肿瘤分次放疗内靶区位移变化.方法 29例胸段食管癌患者分别于放疗前及放疗10、20、30次时行4DCT模拟定位增强扫描,获得各时相原发肿瘤大体肿瘤体积(GTV)及内大体肿瘤体积(IGTV).比较同次4DCT扫描所得胸上、中、下段食管癌GTV三维方向位移差异,各时段4DCT扫描所得同段食管癌GTV间同一方向位移差异及疗程中IGTV空间位置和体积变化.结果 胸中段患者初次及放疗20次时GTV位移在左右、前后、上下方向均不同(P=0.000 ~0.016),放疗10次时GTV位移上下与左右、前后方向均不同(P =0.000 ~0.006);胸下段患者初次及放疗10、20次时GTV位移上下与前后方向也不同(P=0.004~0.013);放疗疗程中不同治疗时段间GTV同一方向位移均相似(P=0.102 ~0.823).疗程中IGTV空间位置变化不明显(P =0.689 ~0.999),而其体积在放疗20次时缩小最明显(P =0.012~0.029).结论 放疗疗程中不同时段同一部位食管癌同一方向位移变化并不明显,尽管放疗20次时IGTV明显缩小但疗程中其空间位置变化不大. Objective To investigate the target volume displacements of primary thoracic esophageal carcinoma (TEC) based on repeated enhanced four-dimensional computed tomography (4DCT) scans during fractionated radiotherapy.Methods Twenty-nine patients with TEC underwent enhanced 4DCT before and in the 10th,20th,and 30th fractions of radiotherapy to delineate the gross tumor volumes (GTVs) and internal gross tumor volumes (IGTVs) in all phases.The GTV displacements of upper,middle,or lower TEC in three-dimensional directions in each time of 4DCT were compared,and the GTV displacements of upper,middle,or lower TEC in the same direction in all 4DCT scans were also compared.The changes in the centroid positions and volumes of IGTV during radiotherapy were determined.Results For the patients with middle TEC,significant differences were found between the GTV displacements in leftright (LR) direction,anterior-posterior (AP) direction,and superor-inferior (SI) direction when 4DCT was performed before or in the 20th fraction of radiotherapy (P =0.000-0.016),and significant differences were found between the GTV displacements in SI direction and LR and AP directions when 4DCT was performed in the 10th fraction of radiotherapy (P =0.000-0.006).For the patients with lower TEC,there were significant differences between the GTV displacements in SI direction and AP direction when 4DCT was performed before or in the 10th or 20th fraction of radiotherapy (P =0.004-0.013).There were no significant differences between the GTV displacements in the same direction in all 4DCT scans (P =0.102-0.823).There were no significant changes in the centroid positions of IGTV during radiotherapy (P =0.6 8 9-0.999),and the most significant decreases in IGTV volumes were seen in the 20th fraction of radiotherapy (P =0.012-0.029).Conclusions Under free breathing,the GTV displacement of upper,middle,or lower TEC in the same direction shows no significant changes in different 4DCT scans during radiotherapy;the IGTV volumes decrease significantly in the 20th fraction of radiotherapy,but there are no significant changes in the centroid positions of IGTV during radiotherapy.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2013年第6期450-454,共5页 Chinese Journal of Radiation Oncology
基金 山东省科技发展计划项目(2011YD18039) 山东省科技发展计划项目(2011YD18082)
关键词 食管肿瘤 放射疗法 体层摄影术 X线计算机 四维 大体肿瘤体积 分次内靶区位移 Keywords:Esophageal neoplasm/ radiotherapy Tomography, X-ray computed, four-dimensional Gross tumor volume Intrafraction target displacement
  • 相关文献

参考文献10

二级参考文献65

  • 1朱广迎,石安辉,吴昊,余荣,韩树奎.肺癌调强放疗中靶区规划新概念—IGTV和ICTV[J].中华放射肿瘤学杂志,2006,15(1):72-72. 被引量:13
  • 2罗京伟,傅卫华,阎蒂,吴秋文,徐国镇,高黎.头颈部癌调强放疗过程中腮腺及靶区体积变化的临床分析[J].中华放射肿瘤学杂志,2006,15(2):129-132. 被引量:33
  • 3Barker JL, Garden AS, Ang KK, et al. Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head- and-neck cancer using an CT/linear accelerator system. Int J Radiat Oncol Biol Phys,2004,59:960-970.
  • 4Hansen EK,Bucci MK,Quivey JM,et al. Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer. Int J Radiat Oncol Biol Phys,2006,64:355-362.
  • 5Landoni V, Saracino B, Marzi S, et al. A study of the effect of setup errors and organ motion on prostate cancer treatment with IMRT. Int J Radiat Oncol Biol Phys ,2006,65:587-594.
  • 6Chen YJ, Han C, Liu A, et al. Setup variations in radiotherapy of esophageal cancer: evaluation by daily megavoltage computed tomographic localization. Int J Radiat Oncol Biol Phys, 2007,68 : 1537-1545.
  • 7Yaremko BP, Guerrero TM, McAleer MF, et al. Determination of respiratory motion for distal esophagus cancer using four-dimensional computed tomography. Int J Radiat Oncol Biol Phys,2008, 70:804-810.
  • 8Zhao KL, Liao ZX, Bucci MK, et al. Evaluation of respiratory-induced target motion for esophageal tumors at the gastroesophageal junction. Radiother Oncol,2007,84:283-289.
  • 9Li G, Citrin D, Camphansen K, et al. Advances in 4D medical imaging and 4D radiation therapy. Technol Cancer Res Treat, 2008, 7:67-81.
  • 10Giraud P, Yorke E, Jiang S, et al. Reduction of organ motion effects in IMRT and conformal 3D radiation delivery by using gating and tracking techniques. Cancer Radiother, 2006, 10:269 - 282.

共引文献33

同被引文献29

  • 1李夷民,林勤,王丽琛,孙龙,戴明明,罗作明,郑华,赵龙,吴华.序贯18F-FDG PET/CT显像在非手术治疗食管癌同步放化疗疗效预测中的价值[J].中华核医学与分子影像杂志,2013,33(6). 被引量:3
  • 2Wang W,Li J,Zhang Y,et al.Comparison of patient-specific internal gross tumor volume for radiation treatment of primary esophageal cancer based separately on three-dimensional and four-dimensional computed tomography images[J].Dis Esophagus,2014,27(4):348-354.
  • 3Zhao KL,Liao Z,Bucci MK,et al.Evaluation of respiratoryinduced target motion for esophageal tumors at the gastroesophageal junction[J].Radiother Oncol,2007,84(3):283-289.
  • 4Hof H,Rhein B,Haering P,et al.4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours:comparison with a conventional technique using individual margins[J].Radiother Oncol,2009,93(3):419-423.
  • 5Ezhil M,Vedam S,Balter P,et al.Determination of patientspecific internal gross tumor volumes for lung cancer using fourdimensional computed tomography[J].Radiat Oncol,2009,4:4.
  • 6Harris E J,Donovan EM,Yarnold JR,el al.Characterization of target volume changes during breast radiotherapy using implanted fiducial markers and portal imaging[J].Int J Radiat Oncol Biol Phys,2009,73(3):958-966.
  • 7Wang J,Lin SH,Dong L,et al.Quantifying the interfractional displacement of the gastroesophageal junction during radiation therapy for esophageal cancer[J].Int J Radiat Oncol Biol Phys,2012,83(2):e273-280.
  • 8Britton KR,Starkschall G,Tucker SL,et al.Assessment of gross tumor volume regression and motion changes during radiotherapy for non-small-cell lung cancer as measured by four-dimensional computed tomography[J].Int J Radiat Oncol Biol Phys,2007,68(4):1036-1046.
  • 9Matsugi K,Narita Y,Sawada A,et al.Measurement of interfraction variations in position and size of target volumes in stereotactic body radiotherapy for lung cancer[J].Int J Radiat Oncol Biol Phys,2009,75(2):543-548.
  • 10Underberg RW,Lagerwaard FJ,van Tinteren H,et al.Time trends in target volumes for stage Ⅰ non-small-cell lung cancer after stereotactic radiotherapy[J].Int J Radiat Oncol Biol Phys,2006,64(4):1221-1228.

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部