流动注射化学发光测定天然水中氨氮 被引量:9

Chemiluminescence Determination of Ammoniacal Nitrogen in Natural Waters by Flow Injection Analysis
在线阅读 下载PDF
导出
摘要 基于氨与次氯酸盐反应使次氯酸盐-Luminol化学发光强度降低,建立了氨的流动注射化学发光分析法。试验了各种条件对化学发光强度的影响。测定了天然水中氨氮,回收率为86~95%。 A novel system for the determination of ammonia based on the chemilumines cent reaction between hypochlorite and luminol has been reported. In the basic solution, ammonia reacts with hypochlorite to form monoehloramine which decreases the observed chemiluminescence intensity. The flow injection analysis was used to get the advantages of high speed and automation. Analytical conditions have been optimized. The present method is reproducible with recovery of 86~95%, and applicable to the determination of ammoniacal nitrogen in natural waters.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1991年第3期350-352,共3页 Chinese Journal of Analytical Chemistry
关键词 氨态氮 测定 流动注射分析 Ammoniacal nitrogen, Luminol, Flow Injection analysis, Chemiluminescence
  • 相关文献

参考文献2

  • 1袁有宪,分析化学,1987年,15卷,5期,545页
  • 2团体著者,环境监测分析方法,1983年