期刊文献+

多层螺旋CT肺静脉成像质量与辐射剂量控制研究 被引量:5

Study on Pulmonary Vein Imaging Quality and Radiation Dose by Multi-slice Spiral Computed Tomography
暂未订购
导出
摘要 多层螺旋CT(MSCT)肺静脉成像是房颤射频消融术前的主要影像检查手段。根据心率、体重和心胸比率的不同采用个性化的MSCT扫描方案,适时调整管电压(kv)和管电流(mAs),合理应用心电门控技术,可以在保证MSCT肺静脉成像质量前提下,减低患者所受的辐射剂量。 Pulmonary vein imaging by multi-slice spiral computed tomography is the main imaging examination method before radiofrequency ablation of atrial fibrillation. In order to improve MSCT pulmonary vein imaging quality and reduce the radiation dose of patients, we should take proper MSCT enhancement scaning project according to the heart rate. body weight and the cardiac/chest ratio, adjust tube tension(kv) and tube current(mAs) real time, utilize ECG-gating technique reasonable.
作者 李青 成官迅
出处 《中国CT和MRI杂志》 2013年第5期107-110,共4页 Chinese Journal of CT and MRI
基金 广东省自热科学基金资助课题(编号:S2011010003870)
关键词 X线计算机 体层摄影术 血管造影 肺静脉 辐射剂量 X-ray computed, tomography Angiography Pulmonary vein Radioation dose
  • 相关文献

参考文献13

  • 1ttaissaguerre M, Jais P, Shan DC, et al. Catheter ablation of chronic atrial fibrillation targeting the reinitiating triggers[J]. Journal of Cardiovascular glectrophysiology, 2000, 11 (1): 2.
  • 2单飞,张志勇,曾蒙苏,陈刚,缪熙,刘豪,张力军,曾良斌.心房颤动16层螺旋CT肺静脉造影两种增强方案对比研究[J].放射学实践,2007,22(12):1304-1307. 被引量:6
  • 3Choi SI, Seo JB, Choi Stl, et al. Variation of the Size of Pulmonary Venous Ostia I)nring the Cardiac Cycle: Optimal Reconst ruction Window at ECG-gated Mult i-detector Row CT [J]. Eur Radiol, 2005, 15 (7): 1441-1445.
  • 4Maksimovic R, Cademartiri F, Scholten M, et al. Sixteeen-row Multislice Computed Tomography in the Assessment of Pulmonary Veins Prior to Ablative Treatment: Validation vs Conventional Pulmonary Venography and Study of Reproducibility[J]. Eur Radiol, 2004, 14 (3): 369-374.
  • 5Cronin P, Sneider MB, Kazerooni EA, et al. MDCT of the left atrium andpulmonary veins in planning radiofrequency ablation for atrial fibrillation: a How-to Guide[J]. AJR, 2004, 183(3): 767-778.
  • 6单飞,刘少稳,张志勇.多排螺旋CT肺静脉造影在房颤射频消融术的应用[J].放射学实践,2007,22(6):641-643. 被引量:2
  • 7Lacomis JM, Wigginton W, Fuhrman C, et al. Multi Detector Row CT of the Left Atrium and Pulmonary Veins before Radio-frequency Catheter Ablation for Atrial Fibrillation[J]. Radiographics, 2003,23(Spec):S35-48.
  • 8肖平,谭理连,李扬彬,曹卫国,李树欣,周少萍.16层螺旋CT触发技术在颈部动脉CTA中的临床应用[J].放射学实践,2006,21(5):520-522. 被引量:10
  • 9Zukotynski K, Chan RP, Chow CM, et al. Contrast echocardio-graphy p redicts pulmonary arteriovenous malformations on CT[J]. Chest, 2007, 132(1):18-23.
  • 10Burri E, Duwe J, Kull C, et al. Pulmonary vein thrombosis after lower lobectomy of the left lung[J]. J Cardiovasc Surg, 2006,47(5):609-612.

二级参考文献48

  • 1张子曙,刘军,谭长连,李亚军.颈动脉狭窄的CTA与DSA对照研究[J].中国医学计算机成像杂志,2004,10(3):149-154. 被引量:22
  • 2刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 3谭理连,李扬彬,李树欣,汪全带,李志铭.颅外颈动脉螺旋CT血管造影的临床应用[J].上海医学影像,2003,12(3):186-188. 被引量:5
  • 4高建华,孙宪昶,李剑颖,王贵生,李娜,戴汝平.后置滤过器C_2对64层螺旋CT冠状动脉成像质量的影响[J].中国医学影像技术,2007,23(1):73-76. 被引量:31
  • 5Korogi Y,Takahashi M,Ogura Y,et al.Intracranial Aneurysms:Detection with Three-dimensional CT Angiography with Volume Rendering-Comparision with Conventional Angiographic and Surgical Findings[J].Radiology,1999,211 (2):497-506.
  • 6Claves JL,Wise SW,Hopper KD,et al.Evaluation of Contrast Densities in the Diagnosis of Carotid Stenosis by CT Angiography[J].AJR,1997,169 (3):569-573.
  • 7Borggrefe M, Budde T, Podczeck A, et al. High Frequency Alternating Current Ablation of an Accessory Pathway in Humans[J]. J Am Coll Cardiol, 1987,10(3):576-582.
  • 8Lacomis JM, Wigginton W, Fuhrman C, et al. Multi-detector Row CT of the Left Atrium and Pulmonary Veins before Radio-frequency Catheter Ablation for Atrial Fibrillation[J]. Radiographics, 2003,23 (spec) : S35-50.
  • 9Ghaye B, Szapiro D, Dacher JN, et al. Percutaneous Ablation for Atrial Fibrillation: the Role of Cross-sectional Imaging[J]. Radiographics, 2003,23 (spec) :S19-33.
  • 10Falk R. Atrial Fibrillation[J]. N Engl J Med,2001,344(14): 1067- 1077.

共引文献21

同被引文献32

  • 1刘勇,张华.ALARA理论及CT低剂量应用研究进展[J].中国医学影像技术,2008,24(S1):17-20. 被引量:28
  • 2张丽红,李勇,黄贤会,肖太星,常维平.心电图编辑在提高64排螺旋CT冠状动脉成像质量中的应用[J].医学影像学杂志,2011,21(5):671-674. 被引量:2
  • 3王锦良,李天然,钱根年,肖慧,李铭山.多层螺旋CT血管造影的影像分析[J].临床放射学杂志,2005,24(11):1026-1027. 被引量:24
  • 4Feinberg WM, Blackshear J L , L a u p a c i A , e t a 1. Prevalence, age distribution, and gender of patients with atrial fibrillation. Analysis and implications[J].Arch Intern Med, 1995,155:469-473.
  • 5Hassink RJ, Aretz HT, RuskinJ, et al. Morphology of atrial myocardium in human pulmonary veins: a p in patient atrial f Am Col 1 C of the Am Cardiology, ostmortem analysis s with and without ibrillation[J]. ardiol erican 2003,42: JT-Journal Col lege of 1108-14.
  • 6PapponeC, Rosanio S, Oreto G et al. Circumferential radiofrequency ablation of pulmonary vein ostia: a new anatomic approach for curing atrial fibrillation[J].Circulation, 2000, 102: 2619- 2628.
  • 7Donal E, Yamada H, Leclercq C, et al. The left atrial appendage, a smali, blind-ended structure: a review of its echocardiographic evaluation and its clinical role[J].Chest ,2005,128:1853-62.
  • 8Marom EM, Herndon JE, Kim YH, et al. Variations in pulm venous drainage to the atrium: implications onary left for radio frequency ablation[J] Radiology, 2004,230:824-9.