期刊文献+

64排螺旋CT在头颈部CTA减影中两种扫描方法效果的对比 被引量:9

Comparison of the Effect of Two Kinds Scanning Method of 64-slice Spiral CT on the Hand and Neck CTA Subtraction
暂未订购
导出
摘要 目的:探讨64排螺旋CT在头颈部CTA减影中两种扫描方法的效果,以期提高减影效果和诊断准确率。材料与方法:用64排螺旋CT的两种扫描方法各随机取100例患者的减影图像进行比较,第1种扫描方法系用增强图像减去平扫图像减影方法,第2种扫描方法系用增强第2期图像减去增强第1图像的减影方法。结果:两种方法都能获得减影图像,但他们的减影效果差异较大。结论:第2种扫描方法减影效果明显比第1种扫描方法效果好。 Purpose: To study the effect of two kinds scanning method of 64 - slice spiral CT on the head and neck CTA subtraction, and to improve subtraction effect and the accuracy of diagnosis. Materials and Methods: subtraction ima- ges of random sampling 100 cases separately with two kinds scanning method of 64 - sloe spiral CT ware compared. The first scanning method is using the enhance imaging to subtract plane scan imaging. The second scanning method is using the en- hance second phase imaging to subtract enhance first phase imaging. Results: Bath methods all can abstain subtraction ima- ging , there are significance difference between subtraction effect of them. Conclusion : subtraction effect of the second scan- tling method is superior that the first scanning method.
出处 《现代医用影像学》 2012年第4期214-217,共4页 Modern Medical Imageology
关键词 扫描方法 位移 血管造影技术 减影 Scanning method Displacement Angiography Subtraction
  • 相关文献

参考文献4

二级参考文献33

  • 1张子曙,刘军,谭长连,李亚军.颈动脉狭窄的CTA与DSA对照研究[J].中国医学计算机成像杂志,2004,10(3):149-154. 被引量:22
  • 2谭理连,李扬彬,李树欣,汪全带,李志铭.颅外颈动脉螺旋CT血管造影的临床应用[J].上海医学影像,2003,12(3):186-188. 被引量:5
  • 3Berg MH, Manninen HI, Rasanen HT, et al. CT angiography in the assessment of carotid artery atherosclerosis. Acta Radiol 2002;43:116 - 124
  • 4Phillips CD, Bubash LA. CT angiography and mr angiography in the evaluation of extracranial carotid vascular disease. Radiol Clin North Am 2002; 40:783 - 798
  • 5Cinat M, Lane CT, Pham H, et al. Helical CT angiography in the preoperative evaluation of carotid artery stenosis. J Vasc Surg 1998; 28:290 - 300
  • 6Leclerc X, Godefroy O, Pruvo JP, et al. Computed tomographic angiography for the evaluation of carotid artery stenosis. Stroke 1995; 26:1577 - 1581
  • 7Marcus CD, Ladam V J, Bigot JL, et al. Carotid arterial stenosis:evaluation at CT angiography with the volume - rendering technique. Radiology 1999; 211: 775 - 780
  • 8Randoux B, Marro B, Koskas F, et al. Carotid artery stenosis:prospective comparison of CT, three - dimensional gadolinium enhanced MR, and conventional angiography. Radiology 2001;220:179 - 185
  • 9Marks MP, Napel S, Jordan JE, et al. Diagnosis of carotid artery disease: preliminary experience with maximum- intensity-projection spiral CT angiography. AJR 1993; 160:1267 - 1271
  • 10Cumming M J, Morrow IM. Carotid artery stenosis: a prospective comparison of ct angiography and conventional angiography. A JR 1994; 163:517 - 523

共引文献88

同被引文献62

  • 1王洪生,赵佩林,孙晓峰,刘洪泉,殷尚炯,吕国士,左红,王德韧.64排螺旋CT血管造影诊断颅内动脉瘤[J].中国脑血管病杂志,2007,4(2):59-63. 被引量:19
  • 2吕发金,罗天友,谢鹏,张志伟,沈云,牟君,廖静敏,方维东,陈垦.数字减影CTA图像质量影响因素探讨[J].重庆医科大学学报,2007,32(3):271-274. 被引量:60
  • 3李大鹏,李泓渊.峰值跟踪法颈部CTA扫描成像技术探讨[J].南京医科大学学报(自然科学版),2007,27(11):1346-1348. 被引量:5
  • 4戴汝平.心血管病CT诊断学[M],2版.北京:人民卫生出版社,2013:327-326.
  • 5Lu L, Zhang LJ, Poon CS, et al. Digital subtraction CT angiographyfor detection of intracranial aneurysms: comparison with three-dimen-sional digital subtraction angiography [J], Radiology, 2012,262(2): 613-622.
  • 6Tomura N, Otani T, Sakuma I, et al. There-dimensional bone-freecomputed tomography of aneurysms near the skull basw using a newbone-removal application [J]. Jpn Radiol, 2009, 27(1): 31-36.
  • 7Duffis EJ, Jethwa P, Gupta G. Accuracy of Computed TomographicAngiography al Compared to Digital Subtraction Angiography in theDiagnosis of Intracranial Stenosis and itslmpact on Clinical Deci-sion-making [J].Journal of Stroke and Cerebrovascular Diseases,2012, 22(7): 1013-1017.
  • 8Ari Han, Dae Young Yoon, Eun Soo Kim, et al. Value of CT angiog-raphy for the detection of intracranial vascular lesions in patients withacute severe headache[J]. European Radiology, 2013,23(6): 1443-1449.
  • 9Gang Sun, Juan Ding, Yang Lu, et al. Comparison of Standard- andLow-Tube Voltage 320-Detector Row Volume CT Angiography inDetection of Intracranial Aneurysms with Digital Subtraction An-giography as Gold Standard [J]. Academic Radiology, 2012, 19 (3):281-288.
  • 10Yoon D Y, Lim K J,Choi C S, et al. Detection and characterization of in-tracranial aneurysms with 16-channel multidetector row CT angiogra-phy: A prospective comparison of volume-rendered images and digitalsubtraction angiography [J]. Am J Neuroradiol, 2007, 28(1): 232-235.

引证文献9

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部