摘要
建立了高效液相色谱-串联质谱定量测定纺织品中克莱范(Kelevan)残留的分析方法。样品经甲醇-乙腈(1∶1)混合溶液超声提取,弗罗里硅柱净化,ESI负离子模式下多反应监测(MRM)模式测定。待测物经Hypersil GOLD C18色谱柱分离,以甲醇-5 mmol/L乙酸铵溶液为流动相进行梯度洗脱,外标法定量。结果显示,克莱范在1.0-200.0 μg/L 范围内线性关系良好,定量下限(以信噪比≥10计)为0.025 mg/kg,以0.025、0.250、0.625 mg/kg浓度进行加标后测得回收率为90.6%-103.4%,相对标准偏差为3.3%-5.2% 。本实验建立的方法简便、准确、可操作性强,弥补了国内纺织品中克莱范检测方法的空白。
A high performance liquid chromatography-tandem mass spectrometric(LC-MS/MS) method was developed for the determination of kelevan residue in textiles.The sample was ultrasonically extracted with methanol-acetonitrile(1∶1) and the extract was purified with florisil column if necessary.The compound was separated on a Hypersil GOLD C18 column(100 mm×2.1 mm,5 μm) with 20% methanol-5 mmol/L ammonium acetate aqueous solution as mobile phase.The detection of kelevan was carried out by MS/MS with negative electrospray ionization under the multiple reaction monitoring mode using the external standard method.The calibration curve showed a good linearity in the range of 1.0-200.0 μg/L for the target compound.The limit of quantitation(S/N≥10) was 0.025 mg/kg.The recoveries of kelevan in cotton sample ranged from 90.6% to 103.4% at the spiked levels of 0.025,0.250,0.625 mg/kg with relative standard deviations(RSDs) of 3.3%-5.2%.With advantages of simplicity,accurancy and strong operability,the established method could be applied in the determination of kelevan in textiles.
出处
《分析测试学报》
CAS
CSCD
北大核心
2013年第9期1069-1074,共6页
Journal of Instrumental Analysis
基金
国家检验检疫行业标准制定计划项目(2011B049)
广东出入境检验检疫局科研项目(2009GDK55)
关键词
克莱范
纺织品
液相色谱-串联质谱
kelevan
textiles
liquid chromatography - tandem mass spectrometry( LC - MS/MS)