摘要 高频诊断技术是检测高压交联电缆局部放电的重要方法之一。通过分析高频诊断技术的基本原理,可知传统的高频诊断技术存在无法准确区分局部放电的类型且抗噪声能力较弱的缺陷。笔者在此基础上提出基于模糊聚类分析的局部放电脉冲分离技术。同时从理论分析、实验室验证及现场测试几个方面进行讨论,并通过对测试数据的分析验证了该方法的有效性。 High frequency diagnostic technology is an important method for detecting partial discharge of high voltage XLPE cables. However, the traditional high-frequency diagnostic technology cannot accurately separate different types of partial discharge, and its ability of anti-noise is relatively weak. In this paper, a separation technique of partial discharge pulse is proposed based on fuzzy clustering for XLPE cables. The technique is discussed in terms of theoretical analysis, experimental verification and practical measurement. The validity of the technique is verified by the measured data.
出处 《高压电器》 CAS CSCD 北大核心 2013年第9期102-107,共6页 High Voltage Apparatus
关键词 高压交联电缆 高频 局部放电 模糊聚类 脉冲分离 high voltage XLPE cable high-frequency partial discharge fuzzy clustering pulse separation
  • 相关文献

参考文献24

  • 1蔡敏,刘晓安.XLPE电力电缆局放检测技术的发展和现状[J].西北电力技术,2003,31(4):31-32. 被引量:5
  • 2姜芸,闵虹,夏荣,李文杰.高压交联电缆接头局部放电的电容耦合法检测及分析[J].高电压技术,2010,36(8):2005-2011. 被引量:52
  • 3王长昌,李福祺.电力设备的在线监测与故障诊断[M].北京:清华大学出版社,2006.3.
  • 4徐敏骅,裘简涛.声电联合技术在局部放电检测中的应用[J].上海电力,2011,24(1):70-73. 被引量:7
  • 5KATSUTA G,TOYA A,MURAOKA K,et al. Development of a method partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines[J]. IEEE Transactions on Power Delivery, 1992,7(3) : 1068-1079.
  • 6OHKI Y. Present stage of partial-discharge monitoring technique in after-layilg tests for extra-high voltage XLPE cable lines[J]. IEEE Electrical Insulation Magazine,2000, 16(1) : 74-76.
  • 7WENZEL D,SCHICHLER U,BORSI H,et al. Recognition of partial discharges on power units by directional coupling[J]. The 9th ISH, 1995(5626): 1-4.
  • 8周亚非,秦阳.在线局部放电监测技术的实际应用[J].高电压技术,2001,27(1):30-31. 被引量:13
  • 9HEIZMANN T,ASCHWANDEN T. On-site partial discharge measurements on premoulded cross-bonding joints of 170 kV XLPE and EPR cables[J]. IEEE Transactions on Power Delivery, 1998,13(2) : 59-63.
  • 10SCHICHLER U. A sensitive method for on-site partial discharge detection on XLPE cable joints[J]. The 5th ISH, 1997,5(2) : 1099-1102.

二级参考文献46

共引文献124

同被引文献86

引证文献4

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部