高压并联电容器组作为电力系统中重要的无功补偿装置,对电网的安全稳定运行至关重要。介绍了高压并联电容器在现场试验中遇到的问题,提出了解决办法及注意事项。便于掌握高压并联电容器的试验特点、提高测试精度,避免有隐患的电容器再次投入运行,提高了高压并联电容器的可用率,更好地发挥了高压并联电容器在电网中的作用。
As an important part in the power system of reactive power compensation device, high voltage parallel capacitor group is crucial to the power grid safe and stable operation. Problems occurred in field test concerning high voltage parallel capacitor is mainly introduced, solutions and points for attention are put forward. All these are to facilitate control of high voltage parallel capacitor test characteristics, improve the testing accuracy and avoid hidden dangers of the capacitor again put into operation, improve the availability of high voltage parallel capacitor, play a better role of high voltage parallel capacitor in the power grid.