期刊文献+

激光质谱法探测痕量污染气体的定标研究 被引量:4

Calibration for trace gases detection with laser mass spectrometry
在线阅读 下载PDF
导出
摘要 介绍了一种新的环境污染痕量气体探测方法——激光质谱法,并给出了定标方法.采用甲苯作为定标的标准样品,用这种方法定量检测了汽车尾气的多种有机污染物.理论研究和实验结果表明,激光质谱法是一种有效的痕量污染气体的多组分在线检测方法. In this paper a new method for detection of pollution trace gases with laser mass spectrometry is presented and the calibration procedure is also given. With toluene as calibration gas, organic pollutants from automobile's exhaust gas are determined by the method. It is theoretically and experimentally demonstrated that laser mass spectrometry is an effective tool for trace gases analysis.
出处 《中国环境科学》 EI CAS CSSCI CSCD 北大核心 2000年第5期445-448,共4页 China Environmental Science
关键词 激光质谱法 汽车尾气 有机污染物 定标 废气监测 laser mass spectrometry;automobile's exhaust gas;organic pollutants;calibration
  • 相关文献

参考文献9

  • 1[1] Castaldi M, Senkan S M. Real time, ultrasensitive monitoring of nair toxics by laser photoionization time-of-flight mass aspectrometry [J]. Journal of the Air & Waste Management Association, 1998,48: 77- 81.
  • 2[2] Boesl U,H.Nagel,Weickhardt C, et al. Multicomponent on-line gas analysis using laser mass spectrometry: scientific principle and application to vehicle emission [M]. The Encyclopedia of Environment Analysis and Remediation, preprint, 1997.
  • 3[3]Weickhardt C, Boesl U, Schlag E W. Laser mass spectrometry for
  • 4[4] Letokhov V S. Laser photoionization spectroscopy [M]. Orlando, FL, Academic Press, 1987.
  • 5[5] Zimmermann R, Lenoir D, Kettrup A, et al. On-line emission control of combustion processes by laser-induced resonance-enhanced multi-photon ionization/mass spectrometry [A]. 26th Symposium, (International) on Combustion, the
  • 6[6] Zimmermann R, Heger H, Kettrup A, et al. A mobile resonance-enhanced multiphoton ionization time-of-flight mass spectrometry device for on-line analysis of aromatic pollutants in waste incinerator flue gases: first results [J]. Rapid
  • 7[7] Heger H, Zimmermann R, Dorfner R, et al. On-line emission analysis of polycyclic aromatic hydrocarbons down to pptv concentration levels in the flue gas an incineration pilot plant with a mobile resonance-enhanced multiphoton ionization time-of-flight mass spectrometer [J]. Analytic Chemistry,
  • 81999,71: 46- 57.
  • 9[8] Boesl U, Weickhardt C, Schmit S, et al. Calibration method for the quantitative analysis of gas mixtures by means of multiphoton ionization mass spectrometry [J]. Rew. Sci. Instrum., 1993, 64(12):3482- 3486.

同被引文献6

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部