摘要 在分析喷头布置基本原则的基础上,探讨理想状况下自动喷水灭火系统喷头的布置情况,根据《自动喷水灭火系统设计规范》计算了喷头的间距范围和有效保护半径,认为喷头的布置间距不是仅由喷水强度决定,而是喷水强度、工作压力、流量系数等参数共同作用的结果;喷头的不同布置形式决定了喷头与端墙的距离,在实际工程中应根据实际情况灵活布置喷头。 Based on the distribution principle of sprinkler heads, an ideal distribution of automatic sprinklers is discussed. The spacing range and effective protection radius of sprinkler head is calculated ac- cording to Automatic Sprinkler System Design Specification. It is concluded that the spacing of sprinkler heads is jointly decided by spray strength, working pressure, flow coefficient, and that the distance from sprinkler head to the end wall is determined by the layout of sprinklers. It is thus recommended that the sprin- kler heads should be flexibly arranged in the project according to the circumstances.
作者 费广成
出处 《常州工学院学报》 2013年第1期19-22,共4页 Journal of Changzhou Institute of Technology
关键词 自动喷水灭火系统 喷头间距 流量系数 工作压力 喷水强度 automatic sprinkler system spacing of sprinkler head flow coefficient working pressure spray strength